Abstract
Objective: To describe the accuracy of sonographically guided intra‐articular hip injections with a linear array transducer.Design: Retrospective review.Setting: Private outpatient clinic.Methods: A single experienced operator performed 11 ultrasound‐guided intra‐articular hip injections by using a linear array transducer. Intra‐articular placement was confirmed with contrast agent and fluoroscopy.Main Outcome Measurements: Assessment of injected contrast within the hip joint via fluoroscopic imaging.Results: All 11 sonographically guided hip injections were accurately placed within the hip joint by the use of a linear array transducer (100% accuracy).Conclusion: This retrospective review suggests that physicians who use a linear array transducer can accurately perform intra‐articular hip injections in an outpatient setting.

This publication has 6 references indexed in Scilit: