Combination of solid‐phase affinity capture on magnetic beads and mass spectrometry to study non‐covalent interactions: example of minor groove binding drugs
- 11 October 2005
- journal article
- research article
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 19 (22) , 3307-3314
Abstract
A simple and novel approach was developed to detect non‐covalent interactions. It is based on combination of solid‐phase affinity capture with matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometry (MALDI‐TOFMS). One of the interacting molecules is bound to magnetic beads and is incubated with the target molecules in solution. The complex bound on the solid support is removed from the solution and transferred for MALDI analysis. Mass spectrometry is used only to detect the target compound, which is far more straightforward than detecting the intact non‐covalent complex. To demonstrate the applicability of the method, an AT‐rich oligonucleotide (5′‐CCCCCAATTCCCCC‐3′) and its complementary biotinylated sequence (5′‐biotin‐GGGGGAATTGGGGG‐3′) were hybridized and immobilized to paramagnetic particles by streptavidin‐biotin interaction. The immobilized duplex oligonucleotide was reacted with minor groove binding drugs, Netropsin, Distamycin A, Hoechst 33258 and 4′,6‐diamidino‐2‐phenylindole. The resulting DNA‐drug complex bound to the particles was separated and analyzed by linear MALDI‐TOFMS after washing. Drugs were selectively detected in the spectra. Relative binding strengths were also estimated using competitive complexation. Copyright © 2005 John Wiley & Sons, Ltd.Keywords
This publication has 44 references indexed in Scilit:
- Automated affinity chromatography measurements of compound mixtures using a lab-on-valve apparatus coupled to electrospray ionization mass spectrometryAnalytical Biochemistry, 2004
- Detection of immune complexes by matrix‐assisted laser desorption/ionization mass spectrometryRapid Communications in Mass Spectrometry, 2003
- Investigation of sample preparation and instrumental parameters in the matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometry of noncovalent peptide/peptide complexesRapid Communications in Mass Spectrometry, 2003
- Non-Covalent Complexes between DNA-Binding Drugs and Double-Stranded Oligodeoxynucleotides: A Study by ESI Ion-Trap Mass SpectrometryJournal of the American Chemical Society, 1999
- Non-covalent complexes between DNA-binding drugs and double-stranded deoxyoligonucleotides: a study by ionspray mass spectrometryJournal of Mass Spectrometry, 1997
- Characterisation of the heptameric pore‐forming complex of the Aeromonas toxin aerolysin using MALDI‐TOF mass spectrometryFEBS Letters, 1996
- Mass Spectrometric Mapping of Protein Epitope Structures of Myocardial Infarct Markers Myoglobin and Troponin TBiochemistry, 1996
- Characterization of SH2−Ligand Interactions via LibraryAffinity Selection with Mass Spectrometric DetectionBiochemistry, 1996
- Detection of noncovalent receptor-ligand complexes by mass spectrometryJournal of the American Chemical Society, 1991
- Principles and applications of matrix-assisted UV-laser desorption/ionization mass spectrometryAnalytica Chimica Acta, 1990