Sudden Cardiac Arrest and Death Following Application of Shocks From a TASER Electronic Control Device
- 22 May 2012
- journal article
- case report
- Published by Wolters Kluwer Health in Circulation
- Vol. 125 (20) , 2417-2422
Abstract
Background—The safety of electronic control devices (ECDs) has been questioned. The goal of this study was to analyze in detail cases of loss of consciousness associated with ECD deployment. Methods and Results—Eight cases of TASER X26 ECD–induced loss of consciousness were studied. In each instance, when available, police, medical, and emergency response records, ECD dataport interrogation, automated external defibrillator information, ECG strips, depositions, and autopsy results were analyzed. First recorded rhythms were ventricular tachycardia/fibrillation in 6 cases and asystole (after ≈30 minutes of nonresponsiveness) in 1 case. An external defibrillator reported a shockable rhythm in 1 case, but no recording was made. This report offers evidence detailing the mechanism by which an ECD can produce transthoracic stimulation resulting in cardiac electrical capture and ventricular arrhythmias leading to cardiac arrest. Conclusions—ECD stimulation can cause cardiac electrical capture and provoke cardiac arrest resulting from ventricular tachycardia/ventricular fibrillation. After prolonged ventricular tachycardia/ventricular fibrillation without resuscitation, asystole develops.Keywords
This publication has 28 references indexed in Scilit:
- Presenting Rhythm in Sudden Deaths Temporally Proximate to Discharge of TASER Conducted Electrical WeaponsAcademic Emergency Medicine, 2009
- Successful resuscitation of a patient in asystole after a TASER injury using a hypothermia protocolThe American Journal of Emergency Medicine, 2009
- TASER X26 Discharges in Swine Produce Potentially Fatal Ventricular ArrhythmiasAcademic Emergency Medicine, 2008
- Acute Effects of TASER X26 Discharges in a Swine ModelJournal of Trauma: Injury, Infection & Critical Care, 2007
- Electronic Control Devices and the Clinical MilieuJACC, 2007
- Cardiac Electrophysiological Consequences of Neuromuscular Incapacitating Device DischargesJACC, 2006
- Effects of Cocaine Intoxication on the Threshold for Stun Gun Induction of Ventricular FibrillationJACC, 2006
- Ventricular Fibrillation after Stun-Gun DischargeNew England Journal of Medicine, 2005
- Transcutaneous pacing: Patient tolerance, strength-interval relations and feasibility for programmed electrical stimulationThe American Journal of Cardiology, 1988
- Safety and Efficacy of Noninvasive Cardiac PacingNew England Journal of Medicine, 1983