Venovenous Bypass With a Membrane Lung to Support Bilateral Lung Lavage

Authors:
  • WZWarren M. Zapol
    Warren M. Zapol
  • RWRoger Wilson
    Roger Wilson
  • CHCharles Hales
    Charles Hales
  • DFDavid Fish
    David Fish
  • GCGuillermo Castorena
    Guillermo Castorena
  • AHAlan Hilgenberg
    Alan Hilgenberg
  • DQDeborah Quinn
    Deborah Quinn
  • RKRichard Kradin
    Richard Kradin

Abstract
Partial venovenous cardiopulmonary bypass with a membrane oxygenator was used to exchange respiratory gases during and after bilateral lung lavage in a patient with severe hypoxemia caused by pulmonary alveolar proteinosis. The patient was unable to tolerate an attempt at lung lavage without bypass. Therefore, extracorporeal perfusion safely supported the patient's respiration for 32 hours, buying time to lavage each lung separately and to enable sufficient recovery of transpulmonary gas exchanging capacity. (JAMA 1984;251:3269-3271)