Background Digital subtraction angiography (DSA) is the gold standard imaging for detection of in-stent restenosis (ISR) but there is limited literature on optimal non-invasive surveillance imaging. In this study, the ability of CT angiography (CTA) and MR angiography (MRA) compared with DSA in recognizing ISR was assessed. Methods A single center database of patients treated with stent implantation for ICAD was accessed. All patients who underwent follow-up imaging with DSA paired with either MRA or CTA within 30 days were included. Two angiography readers and two non-invasive imaging readers measured restenosis with a submillimeter digital caliper. ISR was categorized as: none/minimal, mild (Results 17 cases of individual stents that underwent surveillance imaging with paired DSA and CTA and five stents with paired DSA and MRA were identified. Of those undergoing DSA and CTA, inter-reader agreement produced κ=0.68 (95% CI 0.40 to 0.95) for DSA and κ=0.75 (95% CI 0.55 to 0.95) for CTA. Agreement across CTA and DSA was κ=0.36 (95% CI 0.26 to 0.52). Of those undergoing DSA and MRA, inter-reader agreement produced κ=0.71 (95% CI 0.27 to 1.00) for DSA and κ=1.00 (95% CI 1.00 to 1.00) for MRA. Agreement across MRA and DSA was κ=0.34 (95% CI 0.18 to 0.51). Conclusions Good inter-reader agreement exists within DSA, CTA and MRA. However, when comparing non-invasive imaging (CTA and MRA) with DSA, only fair agreement exists. These data suggest that CTA and MRA are not comparable to DSA for evaluation of ISR.Keywords
This publication has 23 references indexed in Scilit:
- Stenting versus Aggressive Medical Therapy for Intracranial Arterial StenosisNew England Journal of Medicine, 2011
- Detection of Intracranial In-Stent Restenosis Using Quantitative Magnetic Resonance AngiographyStroke, 2010
- Contrast-Enhanced Angiographic Cone-Beam CT of Cerebrovascular Stents: Experimental Optimization and Clinical ApplicationAmerican Journal of Neuroradiology, 2010
- Diagnostic Accuracy of 320-Row Multidetector Computed Tomography Coronary Angiography to Noninvasively Assess In-Stent RestenosisInvestigative Radiology, 2010
- DynaCT evaluation of in-stent restenosis following Wingspan stenting of intracranial stenosisJournal of NeuroInterventional Surgery, 2009
- Treatment of Atherosclerotic Intracranial Arterial StenosisStroke, 2009
- Assessment of the Intracranial Stents Patency and Re-Stenosis by 16-Slice CT Angiography with Optimized Sharp Kernel : Preliminary StudyJournal of Korean Neurosurgical Society, 2009
- The NIH registry on use of the Wingspan stent for symptomatic70–99% intracranial arterial stenosisNeurology, 2008
- CT Angiographic Appearance of In-Stent Restenosis of Intracranial Arteries Treated with the Wingspan StentAmerican Journal of Neuroradiology, 2007
- Use of Stents to Treat Intracranial Cerebrovascular DiseaseAnnual Review of Medicine, 2007