Preliminary Evaluation of a Novel Thermoplastic Mask System with Intra-fraction Motion Monitoring for Future Use with Image-Guided Gamma Knife
Authors:
Open Access
- 13 March 2016
- journal article
- research article
- Published by Springer Nature in Cureus
- Vol. 8 (3) , e531
Abstract
A non-invasive immobilization system consisting of a thermoplastic mask with image-guidance using cone-beam CT (CBCT) and infrared (IR) tracking has been developed to ensure minimal inter- and intra-fractional movement during Gamma Knife radiosurgery. Prior to clinical use for patients on a Gamma Knife, this study clinically evaluates the accuracy and stability of this novel immobilization system with image-guidance in patients treated with standard fractionated radiation therapy on a linear accelerator. This prospective cohort study evaluated adult patients planned for fractionated brain radiotherapy. Patients were immobilized with a thermoplastic mask (with the nose cut out) and customized head cushion. A reflective marker was placed on the patient’s nose tip and tracked with a stereoscopic IR camera throughout treatment. For each fraction, a pre-treatment, verification (after any translational correction for inter-fraction set-up variation), and post-treatment CBCT was acquired to evaluate inter- and intra-fraction movement of the target and nose. Intra-fraction motion of the nose tip measured on CBCT and IR tracking were compared. Corresponding data from 123 CBCT and IR datasets from six patients are summarized. The mean ± standard deviation (SD) intra-fraction motion of the nose tip was 0.41±0.36 mm based on pre- and post-treatment CBCT data compared with 0.56±0.51 mm using IR tracking. The maximum intra-fraction motion of the nose tip was 1.7 mm using CBCT and 3.2 mm using IR tracking. The mean ± SD intra-fraction motion of the target was 0.34±0.25 mm, and the maximum intra-fraction motion was 1.5 mm. Conclusions: This initial clinical evaluation of the thermoplastic mask immobilization system using both IR tracking and CBCT demonstrate that mean intra-fraction motion of the nose and target is small. The presence of isolated measures of larger intra-fraction motion supports the need for image-guidance and intra-fraction motion management when using this mask-based immobilization system for radiosurgery.Keywords
This publication has 20 references indexed in Scilit:
- Interfraction and intrafraction performance of the Gamma Knife Extend system for patient positioning and immobilizationJournal of Neurosurgery, 2012
- Performance of a Novel Repositioning Head Frame for Gamma Knife Perfexion and Image-Guided Linac-Based Intracranial Stereotactic RadiotherapyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2010
- THE LEKSELL GAMMA KNIFE PERFEXION AND COMPARISONS WITH ITS PREDECESSORSOperative Neurosurgery, 2007
- Repositioning Accuracy: Comparison of a Noninvasive Head Holder with Thermoplastic Mask for Fractionated Radiotherapy and a Case ReportInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1998
- Repositioning accuracy of a noninvasive head fixation system for stereotactic radiotherapyMedical Physics, 1996
- Adaptation and verification of the relocatable gill-thomas-cosman frame in stereotactic radiotherapyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1994
- A non-invasive, relocatable stereotactic frame for fractionated radiotherapy and multiple imagingRadiotherapy and Oncology, 1991
- Relocatable frame for stereotactic external beam radiotherapyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1991
- Stereotactic radiosurgery.Journal of Neurology, Neurosurgery & Psychiatry, 1983
- The stereotaxic method and radiosurgery of the brain.1951