On the Crack Characteristic Signal From an Open-Ended Coaxial Probe
Authors:
- 22 May 2014
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 63 (7) , 1877-1879
Abstract
Detection of surface-breaking cracks in metals is an important issue in many industries (e.g., transportation, aerospace, nuclear). Commonly, eddy current and ultrasonic techniques are used for this purpose. In recent years, a significant amount of work has also been conducted using microwave methods. Consequently, to better understand the interaction between a microwave probe (i.e., open-ended rectangular waveguide or coax) and a crack, a number of electromagnetic models have been developed. For an open-ended coaxial probe, when a crack coincides with the center conductor region of the probe, all previously developed models significantly underestimate the results obtained from measurements. This paper examines the primary reason for this discrepancy, which turns out to be due to a geometrical perturbation in the probe center conductor geometry and its subsequent interaction with a crack.Keywords
This publication has 8 references indexed in Scilit:
- Output Signal Prediction of an Open-Ended Coaxial Probe When Scanning Arbitrary-Shape Surface Cracks in MetalsIEEE Transactions on Instrumentation and Measurement, 2012
- Depth Evaluation of Shallow Surface Cracks in Metals Using Rectangular Waveguides at Millimeter-Wave FrequenciesIEEE Transactions on Instrumentation and Measurement, 2009
- Microwave and millimetre wave sensors for crack detectionFatigue & Fracture of Engineering Materials & Structures, 2008
- Interaction of an Open-Ended Rectangular Waveguide Probe With an Arbitrary-Shape Surface Crack in a Lossy ConductorIEEE Transactions on Microwave Theory and Techniques, 2006
- Nondestructive Evaluation2002
- Analysis of the "Crack characteristic signal" using a generalized scattering matrix representationIEEE Transactions on Microwave Theory and Techniques, 1997
- A novel microwave method for detection of long surface cracks in metalsIEEE Transactions on Instrumentation and Measurement, 1994
- Microwave Eddy-Current Techniques for Quantitative Nondestructive Evaluation1981