Adsorption of Trace Metals by Tension Lysimeters: Nylon Membrane vs. Porous Ceramic Cup

Authors:

Abstract
Lysimeters constructed of polyacrylic and fitted with either a porous nylon membrane or a porous ceramic cup were tested for their adsorption characteristics with respect to Pb, Cr, Cu, As, Cd, Co, Mn, Ni, and Zn. Laboratory tests were conducted at pH 4, 5, and 6 using metal concentrations that are representative of natural soil solutions. The ceramic lysimeters significantly lowered the concentrations of Cd, Co, Mn, Ni, and Zn, and almost completely removed Pb, Cr, Cu, and As from solution. The nylon lysimeters had virtually no effect on metal concentrations at pH 4 to 5, and only slightly decreased the concentrations of As, Cr, Cu, and Pb at pH 6. Based on field experience, an optimized design of the nylon lysimeter is presented using double nylon membranes to improve the mechanical resistance.