A multiplexed TOF and DOI capable PET detector using a binary position sensitive network
Authors:
- 14 October 2016
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 61 (21) , 7639-7651
Abstract
Time of flight (TOF) and depth of interaction (DOI) capabilities can significantly enhance the quality and uniformity of positron emission tomography (PET) images. Many proposed TOF/DOI PET detectors require complex readout systems using additional photosensors, active cooling, or waveform sampling. This work describes a high performance, low complexity, room temperature TOF/DOI PET module. The module uses multiplexed timing channels to significantly reduce the electronic readout complexity of the PET detector while maintaining excellent timing, energy, and position resolution. DOI was determined using a two layer light sharing scintillation crystal array with a novel binary position sensitive network. A 20 mm effective thickness LYSO crystal array with four 3 mm × 3 mm silicon photomultipliers (SiPM) read out by a single timing channel, one energy channel and two position channels achieved a full width half maximum (FWHM) coincidence time resolution of 180 ± 2 ps with 10 mm of DOI resolution and 11% energy resolution. With sixteen 3 mm × 3 mm SiPMs read out by a single timing channel, one energy channel and four position channels a coincidence time resolution 204 ± 1 ps was achieved with 10 mm of DOI resolution and 15% energy resolution. The methods presented here could significantly simplify the construction of high performance TOF/DOI PET detectors.Keywords
Funding Information
- National Institutes of Health (F31CA171573, R25CA118681, R21EB014405, R01EB011552)
This publication has 18 references indexed in Scilit:
- A feasibility study of a PET/MRI insert detector using strip-line and waveform sampling data acquisitionNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2015
- Side readout of long scintillation crystal elements with digital SiPM for TOF‐DOI PETMedical Physics, 2014
- Signal encoding method for a time-of-flight PET detector using a silicon photomultiplier arrayNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2014
- Predicting the timing properties of phosphor-coated scintillators using Monte Carlo light transport simulationPhysics in Medicine & Biology, 2014
- Investigation of analog charge multiplexing schemes for SiPM based PET block detectorsPhysics in Medicine & Biology, 2013
- Sub-200 ps CRT in monolithic scintillator PET detectors using digital SiPM arrays and maximum likelihood interaction time estimationPhysics in Medicine & Biology, 2013
- Continuous depth-of-interaction measurement in a single-layer pixelated crystal array using a single-ended readoutPhysics in Medicine & Biology, 2013
- Investigating the temporal resolution limits of scintillation detection from pixellated elements: comparison between experiment and simulationPhysics in Medicine & Biology, 2011
- Benefit of Time-of-Flight in PET: Experimental and Clinical ResultsJournal of Nuclear Medicine, 2008
- Recent advances and future advances in time-of-flight PETNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2007