Surface-Enhanced Raman Spectroscopy of Benzenethiol Adsorbed from the Gas Phase onto Silver Film over Nanosphere Surfaces: Determination of the Sticking Probability and Detection Limit Time
- 16 March 2009
- journal article
- research article
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry A
- Vol. 113 (16) , 4581-4586
Abstract
A chemical warfare agent (CWA) gas detector based on surface-enhanced Raman spectroscopy (SERS) using robust nanostructured substrates and a portable Raman spectrometer is a promising alternative to existing modalities. A gas-dosing apparatus was constructed to simulate chemical gas exposure and provide a platform for quantitative analysis of SERS detection. As a first step toward characterizing SERS detection from the gas phase, benzenethiol (BT) has been chosen as the test analyte. SERS spectra were monitored during BT adsorption onto a silver film over a nanosphere (AgFON) substrate. The SERS detection limit time (DLt) for BT on a AgFON at 356 K is found to be 6 ppm-s (30 mg-s m−3) for a data acquisition time (tacq) of 1 s. The DLt for this kinetically controlled sensor is fundamentally determined by the low sticking probability of BT on AgFONs which is determined to be ∼2 × 10−5 at 356 K. The sticking probability increases with increasing temperature consistent with an adsorption activation barrier of ∼13 kJ mol−1. Although the DLts found in the present study for BT are in the low ppm-s, a theoretical model of SERS detection indicates DLts below 1 ppb s−1 for tacq= 1 s are, in fact, achievable using existing portable Raman instrumentation and AgFON surfaces. Achieving this goal requires the sticking probability be increased 3 orders of magnitude, illuminating the importance of appropriate surface functionalization.Keywords
This publication has 37 references indexed in Scilit:
- Miniaturized Low-Cost Ion Mobility Spectrometer for Fast Detection of Chemical Warfare AgentsAnalytical Chemistry, 2008
- High-Sensitivity Ion Mobility Spectrometry/Mass Spectrometry Using Electrodynamic Ion Funnel InterfacesAnalytical Chemistry, 2005
- Development of an ion mobility spectrometer for use in an atmospheric pressure ionization ion mobility spectrometer/mass spectrometer instrument for fast screening analysisRapid Communications in Mass Spectrometry, 2004
- Ion mobility spectrometry: a review. Part 1. Structural analysis by mobility measurementThe Analyst, 2004
- Detection of gas-phase chemical warfare agents using field-portable gas chromatography–mass spectrometry systems: instrument and sampling strategy considerationsTrAC Trends in Analytical Chemistry, 2004
- Spectroscopic Tags Using Dye-Embedded Nanoparticles and Surface-Enhanced Raman ScatteringAnalytical Chemistry, 2003
- Developments in ion mobility spectrometry–mass spectrometryAnalytical and Bioanalytical Chemistry, 2001
- Comparison of the hydrolytic stability ofS-(N,N-diethylaminoethyl) isobutyl methylphosphonothiolate with VX in dilute solutionJournal of Applied Toxicology, 2001
- Raman Cross Sections of Chemical Agents and SimulantsApplied Spectroscopy, 1988
- Recovery of central respiratory function following anticholinesterase intoxicationEuropean Journal of Pharmacology, 1976