Resistive contact region solid armatures: electro-thermal design optimisation

Authors:

Abstract
A general method for the electro-thermal design optimisation of nontransitioning solid armatures with resistive contact regions is presented which predicts the maximum velocity at which transition to an arcing contact occurs. Comparison with a wide range of published experimental results supports the validity of the velocity skin-effect (VSE) model used. It is shown that the optimum combination of armature design parameters with copper rails requires a contact region resistivity within the range of molybdenum to titanium and that transition velocities, as limited by the VSE, of >2.5 km/s should be achieved with 90 mm bore armatures and these optimum parameters.

This publication has 16 references indexed in Scilit: