Examination of cervical spine kinematics in complex, multiplanar motions after anterior cervical discectomy and fusion and total disc replacement
Open Access
- 1 December 2012
- journal article
- Published by International Journal of Spine Surgery in International Journal of Spine Surgery
- Vol. 6 (1) , 190-194
Abstract
The biomechanical behavior of total disc replacement (TDR) and anterior cervical discectomy and fusion (ACDF) incomplex multiplanar motion is incompletely understood. The purpose of this study was to determine whether ACDF or TDR significantly affects in vitro kinematics through a range of complex, multiplanar motions. Seven human cervical spines from C4-7 were used for this study. Intact cervical motion segments with and without implanted TDR and ACDF were tested by use of unconstrained pure bending moment testing fixtures in 7 mechanical modes: axial rotation (AR); flexion/extension (FE); lateral bending (LB); combined FE and LB; combined FE and AR; combined LB and AR; and combined FE, LB, and AR. Statistical testing was performed to determine whether differences existed in range of motion (ROM) and stiffness among spinal segments and treatment groups for each mechanical test mode. ACDF specimens showed increased stiffness compared with the intact and TDR specimens (P < .001); stiffness was not found to be different between TDR and intact specimens. ACDF specimens showed decreased ROM in all directions compared with TDR and intact specimens at the treated level. For the coupled motion test, including AR, LB, and FE, the cranial adjacent level (C4/C5) for the intact specimens (2.7°) showed significantly less motion compared with both the TDR (6.1°, P = .009) and ACDF (6.8°, P = .002) treatment groups about the LB axis. Testing of the C4/C5 and C6/C7 levels in all other test modes yielded no significant differences in ROM comparisons, although a trend toward increasing ROM in adjacent levels in ACDF specimens compared with intact and TDR specimens was observed. This study compared multiplanar motion under load-displacement testing of subaxial cervical motion segments with and without implanted TDR and ACDF. We found a trend toward increased motion in adjacent levels in ACDF specimens compared with TDR specimens. Biomechanical multiplanar motion testing will be useful in the ongoing development and evaluation of spinal motion-preserving implants.Keywords
This publication has 24 references indexed in Scilit:
- Index and Adjacent Level Kinematics After Cervical Disc Replacement and Anterior FusionSpine, 2011
- Anterior Cervical Decompression and Fusion Accelerates Adjacent Segment DegenerationSpine, 2010
- A comparison of outcomes of cervical disc arthroplasty and fusion in everyday clinical practice: surgical and methodological aspectsEuropean Spine Journal, 2009
- Results of the prospective, randomized, controlled multicenter Food and Drug Administration investigational device exemption study of the ProDisc-C total disc replacement versus anterior discectomy and fusion for the treatment of 1-level symptomatic cervical disc diseaseThe Spine Journal, 2009
- Comparison of radiographic changes after ACDF versus Bryan disc arthroplasty in single and bi-level casesEuropean Spine Journal, 2009
- The prevalence of indications and contraindications to cervical total disc replacementThe Spine Journal, 2008
- Disc replacement using Pro-Disc C versus fusion: a prospective randomised and controlled radiographic and clinical studyEuropean Spine Journal, 2006
- Radiculopathy and Myelopathy at Segments Adjacent to the Site of a Previous Anterior Cervical Arthrodesis*Journal of Bone and Joint Surgery, 1999
- Anterior Discectomy and Fusion for Painful Cervical Disc DiseaseSpine, 1998
- Late Radiographic Findings After Anterior Cervical Fusion for Spondylotic MyeloradiculopathySpine, 1993