Delayed presentation of button battery ingestion: a devastating complication
- 6 April 2017
- journal article
- case report
- Published by BMJ in BMJ Case Reports
- Vol. 2017
Abstract
A 12-month-old child presented with a prolonged history of fever, cough and difficulty breathing, which was initially treated as bronchiolitis. She was discharged but presented again to Accident and Emergency department 4 days later with worsening symptom. Following deterioration in the Emergency department, a chest X-ray revealed a button battery in the upper oesophagus. Emergency oesophagoscopy was performed where a 20 mm button battery was removed and a tracheoesophageal fistula was seen 12 mm above the carina. Near total oesophagectomy, cervical oesophagostomy and gastrostomy were performed with a patch repair of the trachea, followed by a bioabsorbable tracheal stent. The patient spent a prolonged period of time in intensive care and was treated with intravenous antibiotics for mediastinitis. This case highlights the difficulty in diagnosis of button batteries when there is no clear history and the devastating consequences of prolonged exposure.Keywords
This publication has 8 references indexed in Scilit:
- Imaging button battery ingestions and insertions in children: a 15-year single-center reviewPediatric Radiology, 2016
- Button battery ingestion in children: a role for angiography?Canadian Journal of Anesthesia/Journal canadien d'anesthésie, 2016
- Management of Ingested Foreign Bodies in ChildrenJournal of Pediatric Gastroenterology and Nutrition, 2015
- Pediatric button battery injuries: 2013 task force updateInternational Journal of Pediatric Otorhinolaryngology, 2013
- Pediatric Battery-Related Emergency Department Visits in the United States, 1990–2009Pediatrics, 2012
- Preventing Battery Ingestions: An Analysis of 8648 CasesPediatrics, 2010
- Emerging Battery-Ingestion Hazard: Clinical ImplicationsPediatrics, 2010
- Ingestion of Cylindrical and Button Batteries: An Analysis of 2382 CasesPediatrics, 1992