Computational Removal of Undesired Mass Spectral Features Possessing Repeat Units via a Kendrick Mass Filter
- 28 September 2018
- journal article
- research article
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 30 (2) , 268-277
Abstract
Polymers are a common component of chemical background which complicates data analysis and can impair interpretation. Undesired chemical background cannot always be addressed via pre-analytical methods, chromatography, or existing data processing methods. The Kendrick mass filter (KMF) is presented for the computational removal of undesired signals present in MS1 spectra. The KMF is analogous to mass defect filtering but utilizes homology information via Kendrick mass scaling in combination with chromatographic retention time and the number of observed signals. The KMF is intended to assist in situations in which current data processing methods to remove background, e.g., blank subtraction, are either not possible or effective. The major parameters affecting KMF were investigated using PEG 400 and NIST standard reference material 1950 (metabolites in human plasma). Further exploration of the KMF performance was tested using an extract of a swab known to contain polymers. An illustrative real-world example of skin analysis with polymeric signal is discussed. The KMF is also able to provide a high-level view of the compositionality of data regarding the presence of signals with repeat units and indicate the presence of different polymers.Keywords
Funding Information
- National Cancer Institute (1R03CA211211-01)
- National Institute of General Medical Sciences (5P41GM103484-07)
This publication has 13 references indexed in Scilit:
- Extension of the Kendrick Mass Defect Analysis of Homopolymers to Low Resolution and High Mass Range Mass Spectra Using Fractional Base UnitsAnalytical Chemistry, 2017
- Enhanced dereplication of fungal cultures via use of mass defect filteringThe Journal of Antibiotics, 2017
- Sharing and community curation of mass spectrometry data with Global Natural Products Social Molecular NetworkingNature Biotechnology, 2016
- Metabolite Profiling of a NIST Standard Reference Material for Human Plasma (SRM 1950): GC-MS, LC-MS, NMR, and Clinical Laboratory Analyses, Libraries, and Web-Based ResourcesAnalytical Chemistry, 2013
- A cross-platform toolkit for mass spectrometry and proteomicsNature Biotechnology, 2012
- The use of mass defect in modern mass spectrometryJournal of Mass Spectrometry, 2012
- Mass defect filter technique and its applications to drug metabolite identification by high‐resolution mass spectrometryJournal of Mass Spectrometry, 2009
- Graphical Method for Analysis of Ultrahigh-Resolution Broadband Mass Spectra of Natural Organic Matter, the Van Krevelen DiagramAnalytical Chemistry, 2003
- Kendrick Mass Defect Spectrum: A Compact Visual Analysis for Ultrahigh-Resolution Broadband Mass SpectraAnalytical Chemistry, 2001
- A Mass Scale Based on CH2 = 14.0000 for High Resolution Mass Spectrometry of Organic Compounds.Analytical Chemistry, 1963