Measurement of tibiofemoral kinematics using highly accelerated 3D radial sampling
Open Access
- 12 June 2012
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 69 (5) , 1310-1316
Abstract
This study investigated the use of dynamic, volumetric MRI to measure 3D skeletal motion. Ten healthy subjects were positioned on a MR‐compatible knee loading device and instructed to harmonically flex and extend their knee at 0.5 Hz. The device induced active quadriceps loading with knee flexion, similar to the load acceptance phase of gait. Volumetric images were continuously acquired for 5 min using a 3D cine spoiled gradient‐echo sequence in conjunction with vastly under‐sampled isotropic projection reconstruction. Knee angle was simultaneously monitored and used retrospectively to sort images into 60 frames over the motion cycle. High‐resolution static knee images were acquired and segmented to create subject‐specific models of the femur and tibia. At each time frame, bone positions and orientations were determined by automatically registering the skeletal models to the dynamic images. Three‐dimensional tibiofemoral translations and rotations were consistent across healthy subjects. Internal tibia rotations of 7.8 ± 3.5° were present with 35.8 ± 3.8° of knee flexion, a pattern consistent with knee kinematic measures during walking. We conclude that vastly under‐sampled isotropic projection reconstruction imaging is a promising approach for noninvasively measuring 3D joint kinematics, which may be useful for assessing cartilage contact and investigating the causes and treatment of joint abnormalities. Magn Reson Med, 2013.Keywords
This publication has 35 references indexed in Scilit:
- Assessing the accuracy and precision of musculoskeletal motion tracking using cine-PC MRI on a 3.0T platformJournal of Biomechanics, 2011
- Automatic determination of anatomical coordinate systems for three-dimensional bone models of the isolated human kneeJournal of Biomechanics, 2010
- Knee muscle forces during walking and running in patellofemoral pain patients and pain-free controlsJournal of Biomechanics, 2009
- New fluoroscopic imaging technique for investigation of 6DOF knee kinematics during treadmill gaitJournal of Orthopaedic Surgery and Research, 2009
- Improved 3D phase contrast MRI with off‐resonance corrected dual echo VIPRMagnetic Resonance in Medicine, 2008
- Using real‐time MRI to quantify altered joint kinematics in subjects with patellofemoral pain and to evaluate the effects of a patellar brace or sleeve on joint motionJournal of Orthopaedic Research, 2008
- The Kinematic Basis of Anterior Cruciate Ligament ReconstructionOperative Techniques in Sports Medicine, 2008
- The contribution of passive-elastic mechanisms to lower extremity joint kinetics during human walkingGait & Posture, 2008
- Validation of three-dimensional model-based tibio-femoral tracking during runningMedical Engineering & Physics, 2008
- The 3D patellar tendon moment arm: Quantified in vivo during volitional activityJournal of Biomechanics, 2007