Detection of arsenic and lead ions in water through validation of the electrothermal atomic absorption method
- 15 March 2024
- journal article
- research article
- Published by Clinical Biotec S.L. in Bionatura Journal
- Vol. 1 (1) , 1-13
Abstract
The validation of the electrothermal spectrometry method for Arsenic and lead determination in water samples guarantees the quality of analytical data. The study was carried out at AQLAB. A theoretical and technical investigation was applied to ensure the reliability and accuracy of the analytical method. Parameters such as INEN standards, Eurachem international standards, AQLAB internal documents and environmental standards were used to validate the process. Several readings were performed on different samples to make calibration curves for As and Pb, evaluate the method's linearity, and obtain information on the slope, intercept and determination coefficient. Statistical calculations were used to determine the limit of detection and quantification, repeatability, reproducibility, trueness and uncertainty. The results show that the hypotheses were fulfilled, calibration curves with determination coefficient higher than 0.995, repeatability standard deviation lower than 16%, calculated F < critical F (4.96), calculated t student < theoretical (2.23), trueness was between 100.29-110.18 and 99.64-107.92%, uncertainty was 20% range 0.005 to 0.10 mg/L and 15% range 0.01- 0.20mg/L, limit of detection was 0.001 and 0.005 mg/L and limit of quantification was 0.01 and 0.02mg/L, respectively. Therefore, the validation method was robust and accurate. Keywords: water samples, analytical data, reliable results, Arsenic, Lead, validationKeywords
This publication has 15 references indexed in Scilit:
- Development of a Quantitative Determination Method for Aluminum Ions in Adsorbed Drugs Using Atomic Absorption Spectrometry with Electrothermal AtomizationPharmaceutical Chemistry Journal, 2022
- Developing early warning systems to predict water lead levels in tap water for private systemsWater Research, 2022
- Validation of an analytical method for the determination of cadmium, lead and mercury in fish and fishery resources by graphite furnace and Cold Vapor Atomic Absorption SpectrometryFood Control, 2021
- Determination of four arsenic species in environmental water samples by liquid chromatography- inductively coupled plasma - tandem mass spectrometryMethodsX, 2021
- Quantification of lead using atomic absorption spectrometry in thermoformed and biodegradable flexible films made from cassava (Manihot esculenta crantz)DYNA, 2018
- Determination of total arsenic and arsenic species in drinking water, surface water, wastewater, and snow from Wielkopolska, Kujawy-Pomerania, and Lower Silesia provinces, PolandEnvironmental Monitoring and Assessment, 2016
- Determination of Total Arsenic in Water Resources: A Case Study of Rivash in Kashmar CityHealth Scope, 2015
- Espectroscopía de absorción atómica con llama y su aplicación para la determinación de plomo y control de productos cosméticosLa Granja, 2012
- The determination of lead in sugar and sweets without digestion by electrothermal atomic absorption spectrometry (ETAAS) with a rhodium chemical modifierFood Additives & Contaminants, 2006
- Electrothermal atomic-absorption spectrometry of arsenic and its application to environmental samplesTalanta, 2002