Failure Analysis of MIM and MIS Structures Using Point-to-Event Distance and Angular Probability Distributions
Open Access
- 11 November 2014
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Device and Materials Reliability
- Vol. 14 (4) , 1080-1090
Abstract
Multiple breakdown (BD) spots are generated in large (>10 -4 cm 2 ) circular and square area metal-insulator-metal and metal-insulator-semiconductor devices using ramped and constant-voltage electrical stresses. Due to the important local thermal effects that take place at the very moment of the formation of the conductive paths spanning the insulating layer, the failure events become visible on the top metal electrode of the structures as a point pattern. The resulting point-to-event distance and angular histograms are compared with the theoretical distributions corresponding to a complete spatial randomness (CSR) process. The location of the voltage probe tip over the top electrode is considered here as the singular point from which the positions of the BD spots are referred to. In this way, we are able to assess the influence of the probe point on the final BD spot distribution. In most of the cases, this distribution is consistent with CSR, but after prolonged electrical stress, a deviation is detected. This departure from CSR is ascribed to the concentration of the current lines in the top electrode toward the center of the structure. The methods reported here are general and can be used for analyzing the generation of similar point patterns occurring in other structures or material systems.Keywords
Funding Information
- Spanish Ministry of Science and Technology
- DURSI of the Generalitat de Catalunya
This publication has 15 references indexed in Scilit:
- Assessing the spatial correlation and conduction state of breakdown spot patterns in Pt/HfO2/Pt structures using transient infrared thermographyJournal of Applied Physics, 2014
- Analysis of the breakdown spot spatial distribution in Pt/HfO2/Pt capacitors using nearest neighbor statisticsJournal of Applied Physics, 2013
- Direct observation of the generation of breakdown spots in MIM structures under constant voltage stressMicroelectronics Reliability, 2013
- On the difference between optically and electrically determined resistivity of ultra-thin titanium nitride filmsApplied Surface Science, 2013
- Nonhomogeneous spatial distribution of filamentary leakage current paths in circular area Pt/HfO2/Pt capacitorsJournal of Vacuum Science & Technology B, 2012
- Theory of Breakdown Position Determination by Voltage- and Current-Ratio MethodsIEEE Transactions on Electron Devices, 2008
- A Valid and Fast Spatial Bootstrap for Correlation FunctionsThe Astrophysical Journal, 2008
- Dielectric breakdown mechanisms in gate oxidesJournal of Applied Physics, 2005
- Repetitive pulse application of self-healing high voltage capacitors2003
- Uncorrelated breakdown of integrated circuitsNature, 2002