Advancements in Visual Field Testing: A Systematic Review of the 24-2C Test Grid
Open Access
- 29 June 2025
- journal article
- review article
- Published by MDPI AG in Bioengineering
- Vol. 12 (7) , 711
Abstract
A systematic review was conducted of studies published up to 30 August 2024. Studies comparing conventional visual field (VF) indices, ability to detect central visual field defects (CVFDs), structure–function (S-F) concordance, and test characteristics across the HVF 24-2C SITA-Faster, 24-2 SITA-Standard/Faster, and 10-2 SITA-Standard/Fast tests were included. Eight studies with 1239 subjects (49.1% male; mean age, 54.8–66.9 years) were analyzed. The 24-2C produced similar global VF indices compared to the 10-2 and 24-2 (Standard/Faster) (ICC = 0.95 and 0.80, p < 0.001), detected more VF defects and CVFD clusters, and demonstrated greater S-F concordance than the 24-2 (Standard/Faster). Although the 10-2 (Standard/Fast) detected significantly more CVFDs and had a greater S-F concordance, the agreement between the 24-2C and 10-2 grids was substantial (ĸ = 0.488 to 0.708). The 24-2C was also faster compared to the 24-2 Standard and 10-2 (Standard/Fast), with comparable false positives, higher false negatives, and fewer fixation losses than the 24-2 Standard. In conclusion, the HVF 24-2C is quicker and identifies more CVFDs than the 24-2 grid, demonstrates high agreement with the 10-2 grid, and aids in CVFD screening.Keywords
This publication has 52 references indexed in Scilit:
- Comparative Analysis of 24-2C, 24-2, and 10-2 Visual Field Tests for Detecting Mild-Stage Glaucoma With Central Visual field DefectsAmerican Journal of Ophthalmology, 2024
- Interpretation of the Visual Field in Neuro-ophthalmic DisordersCurrent Neurology and Neuroscience Reports, 2024
- Progressive Macular Vessel Density Loss and Visual Field Progression in Open-angle Glaucoma Eyes with Central Visual Field DamageOphthalmology Glaucoma, 2023
- Correlation between Central Visual Field Defects and Stereopsis in Patients with Early-to-Moderate Visual Field LossOphthalmology Glaucoma, 2023
- Comparison of 10-2 and 24-2 Perimetry to Diagnose Glaucoma Using OCT as an Independent Reference StandardOphthalmology Glaucoma, 2022
- Ability of 24-2C and 24-2 Grids to Identify Central Visual Field Defects and Structure-Function Concordance in Glaucoma and SuspectsAmerican Journal of Ophthalmology, 2020
- A New SITA Perimetric Threshold Testing Algorithm: Construction and a Multicenter Clinical StudyAmerican Journal of Ophthalmology, 2019
- Comparing 10-2 and 24-2 Visual Fields for Detecting Progressive Central Visual Loss in Glaucoma Eyes with Early Central AbnormalitiesOphthalmology Glaucoma, 2019
- Global Prevalence of Glaucoma and Projections of Glaucoma Burden through 2040Ophthalmology, 2014
- Reliability of Simultaneous Visual Field TestingOphthalmology, 2012