Background This study aimed to understand the status quo of delta checks in Chinese clinical laboratories through a nationwide online survey. Methods The survey was divided into two parts. The first part was a general situation survey in which clinical laboratories had to provide information about the laboratories, including delta checks used. In the second part, clinical laboratories were asked to record the delta check alerts generated in their laboratories from June 1st, 2019 to June 30th, 2019. Results The most frequently used analytes in delta checks were potassium (K), glucose (Glu), creatinine (Cre) for clinical chemistry and hemoglobin (Hgb), platelet (PLT) count and white blood cell (WBC) count for clinical hematology. The median maximum time interval between specimens for all analytes was 5 days. The most commonly used delta check calculation modes in Chinese clinical laboratories were percentage change and absolute change. K and Hgb were the analytes most involved in clinical chemistry and clinical hematology delta check alerts. The most common causes of delta check alerts were that the patients had received treatment, which was followed by the change in the patient's physiological state and interference from hemolysis, lipemia and icterus. The two most common outcomes of delta check alerts were 'no problems found, standard report issued' and 'no problems found, report issued with comment'. Conclusions This study was the first nationwide survey of delta checks in China, the results of which help us to understand the current situation of delta checks in Chinese clinical laboratories.Keywords
This publication has 22 references indexed in Scilit:
- Autoverification in a core clinical chemistry laboratory at an academic medical centerJournal of Pathology Informatics, 2014
- Patient Data AlgorithmsClinics In Laboratory Medicine, 2013
- A Strategic Informatics Approach to AutoverificationClinics In Laboratory Medicine, 2013
- New Decision Criteria for Selecting Delta Check Methods Based on the Ratio of the Delta Difference to the Width of the Reference Range Can Be Generally Applicable for Each Clinical Chemistry Test ItemAnnals of Laboratory Medicine, 2012
- How useful are delta checks in the 21st century? A stochastic-dynamic model of specimen mix-up and detectionJournal of Pathology Informatics, 2012
- Detection of patients with acute kidney injury by the clinical laboratory using rises in serum creatinine: comparison of proposed definitions and a laboratory delta checkAnnals of Clinical Biochemistry: International Journal of Laboratory Medicine, 2011
- Simulations of delta check rule performance to detect specimen mislabeling using historical laboratory dataClinica Chimica Acta, 2011
- Differential application of rate and delta check on selected clinical chemistry testsJournal of Korean Medical Science, 1990
- Multivariate delta check method for detecting specimen mix-up.Clinical Chemistry, 1982
- CUMS and Delta Checks: A Systematic Approach to Quality ControlAmerican Journal of Clinical Pathology, 1974