Grid to Standalone Transition Motion-Sensorless Dual-Inverter Control of PMSG With Asymmetrical Grid Voltage Sags and Harmonics Filtering
Authors:
- 4 September 2013
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 29 (7) , 3463-3472
Abstract
This paper describes a variable-speed motion-sensorless control system for permanent-magnet synchronous generator (PMSG) connected to grid via back-to-back inverters for wind energy generation. The grid-side inverter control system employs proportional-integral (PI) current controllers with cross-coupling decoupling and line-voltage feedforward disturbance compensation. Also, a D-module filter is used to robustly extract the line voltage positive sequence followed by a phase-locked-loop (PLL) based observer to estimate the positive-sequence angle for control, including the case of asymmetric voltages and automatic seamless transfer method from grid connected to stand alone and vice versa. In stand-alone mode, a voltage control scheme with selective harmonic compensation is employed. The PMSG motion-sensorless control system uses an active power controller and a PLL-based observer to estimate the rotor position and speed without using the electromotive force (EMF) integration and initial rotor position. The paper investigates and validates the ride-through performance of this proposed system during asymmetric power grid-voltage sags, transition from grid connected to stand alone and vice versa and voltage harmonics compensation. While some of the aforementioned issues have been treated rather individually in previous conference publications of the authors, the present paper integrates them into a comprehensive control system of PMSG.Keywords
This publication has 31 references indexed in Scilit:
- Phase-Locked Loop Based on Selective Harmonics Elimination for Utility ApplicationsIEEE Transactions on Power Electronics, 2013
- Transition Control Strategy Between Standalone and Grid-Connected Operations of Voltage-Source InvertersIEEE Transactions on Industry Applications, 2012
- Current Control Reference Calculation Issues for the Operation of Renewable Source Grid Interface VSCs Under Unbalanced Voltage SagsIEEE Transactions on Power Electronics, 2011
- Grid Synchronization PLL Based on Cascaded Delayed Signal CancellationIEEE Transactions on Power Electronics, 2011
- Robust frequency-estimation method for distorted and imbalanced three-phase systems using discrete filtersIEEE Transactions on Power Electronics, 2011
- An Active Anti-Islanding Method Based on Phase-PLL PerturbationIEEE Transactions on Power Electronics, 2011
- Three-Phase PLLs With Fast Postfault Retracking and Steady-State Rejection of Voltage Unbalance and Harmonics by Means of Lead CompensationIEEE Transactions on Power Electronics, 2010
- A Novel Control Strategy for Grid-Interactive Inverter in Grid-Connected and Stand-Alone Modes2006
- Flexible Control of Small Wind Turbines With Grid Failure Detection Operating in Stand-Alone and Grid-Connected ModeIEEE Transactions on Power Electronics, 2004
- Seamless transfer of grid-connected PWM inverters between utility-interactive and stand-alone modes2003