Multidetector CT Angiography Versus Digital Subtraction Angiography for Aortoiliac Length Measurements Prior to Endovascular AAA Repair
Authors:
- Peter HerrmannPHPeter Herrmann
- Hans-Peter DinkelHDHans-Peter Dinkel
- 1 October 2004
- journal article
- research article
- Published by International Society of Endovascular Specialists in Journal of Endovascular Therapy
- Vol. 11 (5) , 527-534
Abstract
To assess observer variation between calibrated-catheter digital subtraction angiography (DSA) and software-enhanced multidetector computed tomography angiography (CTA) in measuring vessel length prior to endovascular aortic aneurysm repair (EVAR). Thirty patients (25 men; mean age 65 years, range 61-85) scheduled for EVAR underwent CTA in 4x2-mm collimation using advanced vessel analysis software. CTA measurements were performed twice by 2 blinded readers in random order with at least a 4-week interval between readings. Nine patients were found unsuitable for endovascular repair after the CTA, so DSA was performed in 21 patients for morphometric evaluation of the abdominal aorta and the iliac arteries. The following segments were measured: H1 (aneurysm neck), H2 (lower renal artery to distal aspect of the aneurysm), H3 (lower renal artery to aortic bifurcation), and H4a/H4b (lower renal artery to iliac bifurcations). Length measurements on DSA were made by (1) following the catheter path in the aortic lumen and (2) dividing tortuous vessel anatomy into segments and measuring each segment along an idealized centerline. Addition of the various segments allowed comparison with data obtained from CTA measurements. CTA was performed with good intraobserver agreement for all length parameters except H3 in reader 2 (p<0.05). While good interobserver agreement was demonstrated for CTA over long aortoiliac distances (H4a, H4b), higher interobserver agreement was obtained with DSA for shorter segments (H1, H2). Considerable differences were observed between CTA and DSA for the lengths H2 and H4b. CTA produces better intra and interobserver correlations in measuring vessel length than DSA. It has the potential to replace DSA as an imaging method before EVAR.Keywords
This publication has 26 references indexed in Scilit:
- Does hostile neck anatomy preclude successful endovascular aortic aneurysm repair?Journal of Vascular Surgery, 2003
- Evaluation of aortoiliac aneurysm before endovascular repair: Comparison of contrast-enhanced magnetic resonance angiography with multidetector row computed tomographic angiography with an automated analysis software toolJournal of Vascular Surgery, 2003
- 3-D imaging with MDCTEuropean Journal of Radiology, 2003
- Is aortic angiography necessary for accurate planning of endovascular aortic aneurysm stents?Cardiovascular Surgery, 2003
- Endovascular Repair of Abdominal Aortic AneurysmsAmerican Journal of Roentgenology, 2001
- Precise determination of aortic length in patients with aortic stent grafts: in vivo evaluation of a thinning algorithm applied to CT angiography dataEuropean Radiology, 2001
- Abdominal Aortic Aneurysm Morphology in Candidates for Endovascular Repair Evaluated With Spiral Computed Tomography and Digital Subtraction AngiographyJournal of Endovascular Surgery, 1999
- Imaging Modalities for Aortic EndograftingJournal of Endovascular Surgery, 1997
- Complications of peripheral arteriography:A new system to identify patients at increased riskJournal of Vascular Surgery, 1995
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986