Improving high-intensity focused ultrasound beam imaging via a backscattering suppression algorithm
Authors:
- 20 April 2017
- journal article
- research article
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 56 (5) , 057301
Abstract
In an ultrasound-guided high-intensity focused ultrasound (HIFU) device, a HIFU focal error may be observed in an ultrasound pulse–echo image due to the difference between the HIFU and imaging beam aberrations occurring in the heterogeneous propagative medium, which was verified by simulating the ultrasound beams passing through an abdominal wall. The HIFU focal error could reduce the accuracy of targeting the HIFU focal spot at a tumor. To measure the focal error, HIFU beam imaging based on backscattered wave reconstruction can be used; however, its image qualities deteriorate due to inhomogeneous backscattering. Hence, we proposed a novel backscattering suppression algorithm based on an inverse problem approach to retrieve HIFU beam components. The proposed algorithm was validated in ex vivo experiments in conjunction with focal spot shifts and beam width variations, demonstrating the clear improvement of HIFU beam imaging quality.Keywords
This publication has 39 references indexed in Scilit:
- Numerical estimation of HIFU focal error for breast cancer treatment2013
- Passive imaging with pulsed ultrasound insonationsThe Journal of the Acoustical Society of America, 2012
- Ultrasound beam simulations in inhomogeneous tissue geometries using the hybrid angular spectrum methodIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2012
- Passive cavitation imaging with ultrasound arraysThe Journal of the Acoustical Society of America, 2009
- Transcostal high-intensity-focused ultrasound:ex vivoadaptive focusing feasibility studyPhysics in Medicine & Biology, 2008
- High-intensity focused ultrasound in the treatment of solid tumoursNature Reviews Cancer, 2005
- Simulation of ultrasonic focus aberration and correction through human tissueThe Journal of the Acoustical Society of America, 2003
- Real-time visualization of high-intensity focused ultrasound treatment using ultrasound imagingUltrasound in Medicine & Biology, 2001
- Trans-skull ultrasound therapy: the feasibility of using image-derived skull thickness information to correct the phase distortionIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1999
- A NEW METHOD FOR THE GENERATION AND USE OF FOCUSED ULTRASOUND IN EXPERIMENTAL BIOLOGYJournal of General Physiology, 1942