Differentiation between nerve and adipose tissue using wide-band (350-1,830 nm)in vivodiffuse reflectance spectroscopy
- 4 June 2014
- journal article
- case report
- Published by Wiley in Lasers in Surgery and Medicine
- Vol. 46 (7) , 538-545
Abstract
Background Intraoperative nerve localization is of great importance in surgery. In certain procedures, where nerves show visual resemblance to surrounding adipose tissue, this can be particularly challenging for the human eye. An example of such a delicate procedure is thyroid and parathyroid surgery, where iatrogenic injury of the recurrent laryngeal nerve can result in transient or permanent vocal problems (0.5–2.0% reported incidence). A camera system, enabling nerve-specific image enhancement, would be useful in preventing such complications. This might be realized with hyperspectral camera technology using silicon (Si) or indium gallium arsenide (InGaAs) sensor chips. Methods As a first step towards such a camera, we evaluated the performance of diffuse reflectance spectroscopy by analysing spectra collected during 18 thyroid and parathyroid resections. We assessed the contrast information present in two different spectral ranges, for respectively Si and InGaAs sensors. Two hundred fifty three in vivo, wide-band diffuse reflectance spectra (350–1,830 nm range, 1 nm resolution) were acquired on 52 tissue spots, including nerve (n = 22), muscle (n = 12), and adipose tissue (n = 18). We extracted 36 features from these spectroscopic data: 18 gradients and 18 amplitude differences at predefined points in the tissue spectra. Best distinctive feature combinations were established using binary logistic regression. Classification performance was evaluated in a cross-validation (CV) approach by leave-one-out (LOO). To generalize nerve recognition applicability, we performed a train–test (TT) validation using the thyroid and parathyroid surgery data for training purposes and carpal tunnel release surgery data (10 nerve spots and 5 adipose spots) for classification purposes. Results For combinations of two distinctive spectral features, LOO revealed an accuracy of respectively 78% for Si-sensors and 95% for InGaAs-sensors. TT revealed accuracies of respectively 67% and 100%. Conclusions Using diffuse reflectance spectroscopy we have identified that InGaAs sensors are better suited for automated discrimination between nerves and surrounding adipose tissue than Si sensors. Lasers Surg. Med. 46:538–545, 2014.Keywords
This publication has 38 references indexed in Scilit:
- Medical hyperspectral imaging: a reviewJournal of Biomedical Optics, 2014
- Complications after total thyroidectomyJournal of Visceral Surgery, 2013
- First Place: Renal Oxygenation During Robot-Assisted Laparoscopic Partial Nephrectomy: Characterization Using Laparoscopic Digital Light Processing Hyperspectral ImagingJournal of Endourology, 2013
- Use of Airborne Hyperspectral Imagery to Map Soil Properties in Tilled Agricultural FieldsApplied and Environmental Soil Science, 2011
- Assessment of Renal Oxygenation During Partial Nephrectomy Using Hyperspectral ImagingJournal of Urology, 2011
- Urinary and sexual dysfunction after rectal cancer treatmentNature Reviews Urology, 2010
- An introduction to hyperspectral imaging and its application for security, surveillance and target acquisitionThe Imaging Science Journal, 2010
- Feasibility study of three-nerve-recognizing Lichtenstein procedure for inguinal herniaBritish Journal of Surgery, 2009
- Urinary dysfunction after rectal cancer treatment is mainly caused by surgeryBritish Journal of Surgery, 2008
- Identification of yellow rust in wheat using in-situ spectral reflectance measurements and airborne hyperspectral imagingPrecision Agriculture, 2007