Metal particles and bubbles are two typical impurities in transformer oil that can cause partial discharge (PD) and even electric breakdown. The PD characteristics are closely related to the motions of these impurities in flowing transformer oil. In this paper, the motions of impurities were obtained by a camera and a simulation model at first. Then, we employed three methods, namely, antennas, a non-inductive resistor, and the method recommended by IEC 60270, to measure the PD signals simultaneously. The breakdown experiments of transformer oil containing the metal particles and bubbles were also performed. In terms of these, single PD waveforms, statistical characteristics, and breakdown voltage were obtained. The results showed that the metal particles could excite ultrahigh frequency (300 MHz–3 GHz) PD signals, whereas bubbles only excited signals in the very high-frequency band (30–300 MHz). Moreover, the PDs induced by the metal particles had a higher repetition rate and a smaller amplitude than the PDs induced by bubbles. In addition, the metal particles easily caused PD, whereas bubbles easily led to the breakdown. Possible reasons for different discharge characteristics between the two impurities were discussed on the basis of the motions of impurities and the distortions of electric field.Keywords
Funding Information
- National Natural Science Foundation of China (51377181)
This publication has 36 references indexed in Scilit:
- Analysis of partial discharge activity by a conducting particle in liquid nitrogen under AC voltages adopting UHF techniqueCryogenics, 2010
- Positive and negative streamers in ambient air: measuring diameter, velocity and dissipated energyJournal of Physics D: Applied Physics, 2008
- Partial discharge study in transformer oil due to particle movement under DC voltage using the UHF techniqueElectric Power Systems Research, 2008
- Thermally and electrically induced bubbles in liquid argon and nitrogenIEEE Transactions on Dielectrics and Electrical Insulation, 2002
- The importance of the forces acting on particles in turbulent flowsPhysics of Fluids, 2001
- Modeling of conductive particle behavior in insulating fluids affected by DC electric fieldsIEEE Transactions on Industry Applications, 1998
- Partial discharge distributions in liquid dielectricsIEEE Transactions on Electrical Insulation, 1992
- The theory and measurement of partial discharge transientsIEEE Transactions on Electrical Insulation, 1991
- The measurement of charge on single particles in transformer oilIEEE Transactions on Electrical Insulation, 1991
- Prebreakdown density change, current and light emission in transformer oil under non-uniform fieldJournal of Electrostatics, 1982