Effects of donor cause of death, ischemia time, inotrope exposure, troponin values, cardiopulmonary resuscitation, electrocardiographic and echocardiographic data on recipient outcomes: A review of the literature
Authors:
- Michael A. McCullochMMMichael A. McCulloch
- Warren A. ZuckermanWZWarren A. Zuckerman
- Thomas MöllerTMThomas Möller
- Kenneth KnechtKKKenneth Knecht
- Kimberly Y. LinKLKimberly Y. Lin
- Gary S. BeasleyGary S. Beasley
- David M. PengDPDavid M. Peng
- Dimpna C. AlbertDADimpna C. Albert
- Oliver MieraOMOliver Miera
- Anne I. DipchandADAnne I. Dipchand
- Richard KirkRKRichard Kirk
- Ryan R. DaviesRDRyan R. Davies
- 21 March 2020
- journal article
- review article
- Published by Wiley in Pediatric Transplantation
- Vol. 24 (3) , e13676
Abstract
Background: Heart transplantation has become standard of care for pediatric patients with either end‐stage heart failure or inoperable congenital heart defects. Despite increasing surgical complexity and overall volume, however, annual transplant rates remain largely unchanged. Data demonstrating pediatric donor heart refusal rates of 50% suggest optimizing donor utilization is critical. This review evaluated the impact of donor characteristics surrounding the time of death on pediatric heart transplant recipient outcomes.Methods: An extensive literature review was performed to identify articles focused on donor characteristics surrounding the time of death and their impact on pediatric heart transplant recipient outcomes.Results: Potential pediatric heart transplant recipient institutions commonly receive data from seven different donor death‐related categories with which to determine organ acceptance: cause of death, need for CPR, serum troponin, inotrope exposure, projected donor ischemia time, electrocardiographic, and echocardiographic results. Although DITs up to 8 hours have been reported with comparable recipient outcomes, most data support minimizing this period to <4 hours. CVA as a cause of death may be associated with decreased recipient survival but is rare in the pediatric population. Otherwise, however, in the setting of an acceptable donor heart with a normal echocardiogram, none of the other data categories surrounding donor death negatively impact pediatric heart transplant recipient survival.Conclusions: Echocardiographic evaluation is the most important donor clinical information following declaration of brain death provided to potential recipient institutions. Considering its relative importance, every effort should be made to allow direct image visualization.Keywords
This publication has 84 references indexed in Scilit:
- Donor-Derived Infections in Solid Organ TransplantationAmerican Journal of Transplantation, 2013
- Electrocardiographic Characteristics of Potential Organ Donors and Associations With Cardiac Allograft UseCirculation: Heart Failure, 2012
- Donor scoring system for heart transplantation and the impact on patient survivalThe Journal of Heart and Lung Transplantation, 2012
- Impact of Donor Left Ventricular Hypertrophy on Survival After Heart TransplantAmerican Journal of Transplantation, 2011
- Corrected QT Interval in Children With Brain DeathPediatric Cardiology, 2010
- Echocardiography in the Potential Heart DonorTransplantation, 2010
- Donor cardiac troponin-I: a biochemical surrogate of heart function☆☆☆European Journal of Cardio-Thoracic Surgery, 2009
- Brain Death Effects on Catecholamine Levels and Subsequent Cardiac Damage Assessed in Organ DonorsThe Journal of Heart and Lung Transplantation, 2009
- Plasma B‐type natriuretic peptide levels in cardiac donorsClinical Transplantation, 2009
- Plasma B-type natriuretic peptide monitoring to evaluate cardiovascular function prior to organ procurement in patients with brain deathPediatric Anesthesia, 2008