Differential diagnosis of lymphocytosis in routine laboratory practice: Contribution of lymphocyte parameters using the Sysmex‐XN9000 haematology analyzer
- 22 May 2023
- journal article
- research article
- Published by Wiley in International Journal of Laboratory Hematology
- Vol. 45 (5) , 685-690
Abstract
Introduction: This study investigates the potential contribution of structural and dispersion parameters, as well as alarms provided by Sysmex XN9000 haematology analyzer. The objective was to assess the need for a microscopic examination in the context of lymphocytosis. It also aims to contribute in differentiating rapidly lymphoproliferative disorders such as chronic lymphocytic leukaemia (CLL), non‐chronic lymphocytic leukaemia (NON‐CLL) and non‐infectious reactive lymphocytosis (REAC).Methods: We prospectively assessed lymphocyte parameters (Ly‐X, Ly‐Y, Ly‐Z, Ly‐WX, Ly‐WY, Ly‐WZ) provided by the Sysmex XN9000 analyzer; they were measured in the white blood cell differential (WDF) channel which also provides alarms via the precursor/pathological cellular channel (WPC). Blood samples from 71 subjects with CLL, NON‐CLL lymphoproliferative and REAC non‐infectious reactive lymphocytosis, as well as a control (NORM) group of 12 subjects without any abnormalities were analyzed.Results: The most discriminating parameters to distinguish the different groups were Ly‐X, Ly‐Z and Ly‐WZ. The lymphoid structural parameters Ly‐X and Ly‐Z significantly discriminated the CLL group from the other groups (p < 0.001), and the CLL group from the REAC group (p < 0.01), respectively. The Ly‐WZ parameter discriminated the CLL group from the NON‐CLL, REAC (p < 0.001) and NORM (p < 0.01) groups. Alarms were higher in all study groups compared to the NORM group. An algorithm integrating these structural and alarm parameters is proposed.Conclusion: This study demonstrated that Ly‐X, Ly‐Z, and Ly‐WZ lymphocyte parameters are useful for detecting morphological changes in lymphocytes; they provide useful information for the differential diagnosis of lymphocytosis, and this before the examination of the blood smear. An algorithm combining the WDF (parameters) and the WPC (alarms) makes it possible to decide whether or not to use a microscopic examination or flow cytometry immunophenotyping.Keywords
This publication has 7 references indexed in Scilit:
- The structural parameters and flags of the Sysmex XN™ analyser: Are they discriminative between reactive and malignant lymphocytosis in the context of lymphocyte counts above 5 × 109/L in adults?International Journal of Laboratory Hematology, 2021
- The integration of Sysmex XN‐9100’ WPC channel reflex testing in the detection of reactive versus malignant blood samplesInternational Journal of Laboratory Hematology, 2020
- A Preliminary Proposal for Quality Control Assessment and Harmonization of Leukocytes Morphology-Structural Parameters (Cell Population Data Parameters)Journal of Medical Biochemistry, 2018
- Usefulness of the lymphocyte positional parameters in the Sysmex XN haematology analyser in lymphoproliferative disorders and mononucleosis syndromeInternational Journal of Laboratory Hematology, 2017
- Sensitivity of the Sysmex XN9000 WPC-channel for detection of monoclonal B-cell populationsClinical Chemistry and Laboratory Medicine (CCLM), 2017
- Flagging performance of the Sysmex XN2000 haematology analyserInternational Journal of Laboratory Hematology, 2016
- Alarms and Parameters Generated by Hematology Analyzer: New Tools to Predict and Quantify Circulating Sezary CellsJournal of Clinical Laboratory Analysis, 2014