Treatment of a benign colorectal anastomotic stricture with a biodegradable stent

Authors:

Abstract
It is routine practice to use metal stents in the treatment of malign obstructions in the lower gastrointestinal tract [ 1 ]. However, metal stents are not suitable for benign conditions. Recently, treatment with biodegradable stents has been implemented for non-malignant diseases in the upper gastrointestinal tract [ 2 ] [ 3 ], but there is no case in the literature reporting on the use of biodegradable stents for benign conditions in the lower gastrointestinal tract. Here we describe a case with a benign stricture in a colorectal anastomosis, treated with a biodegradable stent. A 68-year-old man underwent sigmoid stoma reversal after Hartmann’s procedure (for perforated diverticulitis). The patient developed a symptomatic stricture in the colorectal anastomosis ([ Fig. 1 ]), and biopsies were benign. Despite three endoscopic dilations, the patient suffered from repeated symptomatic stricture recurrence. Due to significant co-morbidity, the patient was not suitable for surgical treatment. As an alternative approach, a self-expanding biodegradable esophageal stent (SX-Ella stent; ELLA-CS, Hradec Kralove, Czech Republic) was chosen. The lumen of the stricture was less than 5 mm and was dilated up to 12 mm. The biodegradable stent was deployed in the middle of the stricture using a guide wire ([ Fig. 2 ]). The position of the stent was monitored 4 days later and the lumen further dilated to 15 mm. The stent position was monitored 6 weeks after deployment; the stent was shown to be partially reabsorbed ([ Fig. 3 ]). The patient was still asymptomatic and a colonoscopy revealed complete biodegradation of the stent 5 months later ([ Fig. 4 a ]). At this time, the lumen had reduced to 8 mm ([ Fig. 4 b ]) and was therefore dilated up to 18 mm. A follow-up was performed 2 years later, which revealed that the patient had no clinical symptoms although the size of the lumen had reduced. Fig. 1 The colorectal stricture visualized by use of: a contrast colonography (the arrow indicates the stricture at the colorectal anastomosis) and b endoscopy. The 2-cm long advanced stricture had a lumen less than 5 mm in diameter. Fig. 2 Appearance of the biodegradable stent immediately after insertion, visualized by use of: a plain abdominal radiograph (arrows indicate the stent in place) and b endoscopy. Fig. 3 Endoscopic images 6 weeks after stenting showing partial biodegradation of the stent in the: a proximal and b distal part of the colorectal stricture. Fig. 4 Endoscopic images 5 months after stenting, showing complete disappearance of the stent with a patent lumen in the: a proximal and b distal part of the colorectal stricture, as well as a hyperplastic tissue reaction. This unique case demonstrates that treatment with biodegradable stents is also feasible in patients with benign strictures in the lower gastrointestinal tract. Endoscopy_UCTN_Code_TTT_1AQ_2AF