The biomechanical performance of locking plate fixation with intramedullary fibular strut graft augmentation in the treatment of unstable fractures of the proximal humerus
Authors:
- 1 July 2011
- journal article
- research article
- Published by British Editorial Society of Bone & Joint Surgery in The Journal of Bone and Joint Surgery. British volume
- Vol. 93-B (7) , 937-941
Abstract
We evaluated the biomechanical properties of two different methods of fixation for unstable fractures of the proximal humerus. Biomechanical testing of the two groups, locking plate alone (LP), and locking plate with a fibular strut graft (LPSG), was performed using seven pairs of human cadaveric humeri. Cyclical loads between 10 N and 80 N at 5 Hz were applied for 1 000 000 cycles. Immediately after cycling, an increasing axial load was applied at a rate of displacement of 5 mm/min. The displacement of the construct, maximum failure load, stiffness and mode of failure were compared. The displacement was significantly less in the LPSG group than in the LP group (p = 0.031). All maximum failure loads and measures of stiffness in the LPSG group were significantly higher than those in the LP group (p = 0.024 and p = 0.035, respectively). In the LP group, varus collapse and plate bending were seen. In the LPSG group, the humeral head cut out and the fibular strut grafts fractured. No broken plates or screws were seen in either group. We conclude that strut graft augmentation significantly increases both the maximum failure load and the initial stiffness of this construct compared with a locking plate alone.Keywords
This publication has 24 references indexed in Scilit:
- Pathological fractures of the proximal humerus treated with a proximal humeral locking plate and bone cementThe Journal of Bone and Joint Surgery. British volume, 2010
- Proximal humeral fractures with a severe varus deformity treated by fixation with a locking plateThe Journal of Bone and Joint Surgery. British volume, 2010
- Open Reduction and Internal Fixation of Proximal Humerus Fractures Using a Proximal Humeral Locked Plate: A Prospective Multicenter AnalysisJournal of Orthopaedic Trauma, 2009
- Early Complications in Proximal Humerus Fractures (OTA Types 11) Treated With Locked PlatesJournal of Orthopaedic Trauma, 2008
- Displacement/Screw Cutout After Open Reduction and Locked Plate Fixation of Humeral FracturesJournal of Bone and Joint Surgery, 2008
- Current concepts in plate and screw fixation of osteoporotic proximal humerus fracturesInjury, 2007
- HYBRID LOCKED PLATING OF OSTEOPOROTIC FRACTURES OF THE HUMERUSJournal of Bone and Joint Surgery, 2006
- Fixation of Proximal Humerus Fractures Using the PHILOS PlateClinical Orthopaedics and Related Research, 2006
- Biomechanics of Locked Plates and ScrewsJournal of Orthopaedic Trauma, 2004
- Locking Compression Plates for Osteoporotic Nonunions of the Diaphyseal HumerusClinical Orthopaedics and Related Research, 2004