Abstract
Regular subsea inspect ion of offshore structures to assess the condition of cathodic protect ion systems is a way of 1ife in the Gulf of Mexico. In an effort to collect more useful data, new inspect ion procedures were implemented into the ARCO Oil and Gas Southern District platform inspections to see if it was possible to routinely calculate the current output of anodes using the anode resistance method in NACE RP-01-76. By trial and error, a potential sampling technique was discovered which allows the collection of the kind of potential data needed to calculate anode current with an accuracy similar to that possible with direct measurement with a gauss meter. The speed at which this data can be taken makes this survey technique no more costly than a normal potential survey while providing much more useful data. INTRODUCTION: A typical underwater potential survey consists of measuring the potential of the structure against a standard reference electrode (usually Ag/AgCl) in order to insure the viability of the cathodic protection system. Although a great deal of data can be obtained, it is usually necessary to limit the scope of the potential survey to keep the time and cost reasonable. When planning for the ARCO Southern District 1989 platform surveys, a complete rethinking of our platform survey requirements was done to try and take the best advantage of the changes caused by the new MMS platform survey requirements. As part of this rethinking, the idea of using potential measurements to survey anode current output was discussed with the survey contractor. It was felt that a usable correlation could be found between anode potential and anode current output using the calculation method recommended in NACE RP-O1-76. This was considered to be an "easy" addition to our survey that could be accomplished without an increase in effort. The main unknown factor was the proper location of the potential survey points needed to give the proper anode and cathode potentials for the calculation. Ideas on how to obtain the needed data were developed and added to the survey procedures prior to the start of work. In order to have a standard against which to compare the results, an underwater gauss meter was obtained for taking anode current measurements directly from the anode supports. During the surveys, direct current measurements and anode potentials were taken on 57 anodes on 13 different platforms. ANOOE CURRENT CALCULATIONS: In theory, the output of an anode can be found by using the equation:I = E/R (1) where I is the current, E is the potential difference between the anode and cathode and R is the circuit resistance. Since the current density is much higher at the anode than the cathode and the resistance in the steel is negligible, the circuit resistance can be considered to be the anode to electrolyte resistance.