Selective determination of lysine in mozzarella cheese using a novel potentiometric biosensor
- 2 January 2023
- journal article
- research article
- Published by Taylor & Francis in Food Biotechnology
- Vol. 37 (1) , 41-53
Abstract
The analysis of lysine represents a significant cost for the relevant food industries. The use of an enzymatic sensor would allow the reduction of time and cost of this analysis. An enzymatic sensor using lysine -α- oxidase (LOx) with a soluble enzyme sensor in combination with an oxygen electrode was optimized in this study to determine the lysine content in mozzarella cheese. Selective determination of lysine in mozzarella cheese is an indicator of quality and of ripening time. The potentiometric signal obtained due to oxygen depletion (consumed oxygen) during lysine oxidation was carried out during 100s in the soluble enzyme sensor. An optimal time sensor response to quantify the lysine content of 3.5s was calculated from the slope of reaction rates. The sensor was set at a potential of 0.6 mV. A positive linear relationship was found between consumed oxygen as a function of time (mg O2/L × s) and lysine concentration in the range of 30–1,300 µM, with a coefficient of R2 = 0.9968 for the soluble enzyme sensor. This system showed good specificity (KM = 0.03 mM), which continued during eight weeks of cheese ripening time. The analysis of lysine with the soluble enzyme sensor in mozzarella cheese samples revealed very good agreement with the determination performed through standard HPLC methodology, which validated the use of this sensor as an alternative and more efficient technique to evaluate dairy products.Keywords
This publication has 23 references indexed in Scilit:
- A highly selective and colorimetric assay of lysine by molecular-driven gold nanorods assemblyBiosensors and Bioelectronics, 2012
- RECENT HPLC STRATEGIES TO IMPROVE SENSITIVITY AND SELECTIVITY FOR THE ANALYSIS OF COMPLEX MATRICESInstrumentation Science & Technology, 2012
- An enzyme sensor for the determination of total amines in dry-fermented sausagesJournal of Food Engineering, 2011
- Hypoxanthine-based enzymatic sensor for determination of pork meat freshnessFood Chemistry, 2010
- Residue-Specific pKa Determination of Lysine and Arginine Side Chains by Indirect 15N and 13C NMR Spectroscopy: Application to apo CalmodulinJournal of the American Chemical Society, 2007
- Sensitive determination of l-lysine with a new amperometric microbial biosensor based on Saccharomyces cerevisiae yeast cellsBiosensors and Bioelectronics, 2007
- Flow Injection Analysis System forl-Lysine Estimation in Foodstuffs Using a Biosensor Based on Lysine Oxidase Immobilization on a Gold-Poly(m-Phenylenediamine) ElectrodeAnalytical Letters, 2003
- Construction of a ?-lysine biosensor by immobilizing lysine oxidase on a gold-poly(o-phenylenediamine) electrodeTalanta, 2000
- Amperometric determination of lysine using a lysine oxidase biosensor based on rigid-conducting composites1Presented at BIOSENSORS 98, Berlin, Germany, 3–5 June 1998.1Biosensors and Bioelectronics, 1999
- Determination of amino acids in biological, pharmaceutical, plant and food samples by automated precolumn derivatization and high-performance liquid chromatographyJournal of Chromatography B: Biomedical Sciences and Applications, 1988