18F-FDG PET in Pregnancy and Fetal Radiation Dose Estimates
Open Access
- 16 June 2011
- journal article
- Published by Society of Nuclear Medicine in Journal of Nuclear Medicine
- Vol. 52 (7) , 1035-1040
Abstract
The purpose of this study was to estimate the fetal radiation exposure resulting from 18F-FDG PET procedures performed in pregnant patients with malignancies. Methods: Five pregnant patients with a biopsy-proven diagnosis of malignancy who underwent 18F-FDG PET studies were retrospectively reviewed. All patients underwent PET-only studies (and not PET/CT studies) with a reduced 18F-FDG dose (except for 1 patient who had a negative pregnancy test immediately before the 18F-FDG PET procedure but was confirmed to be pregnant a few weeks later), including vigorous hydration and diuresis to minimize radiation exposure to the fetus. One patient underwent 18F-FDG PET twice during her pregnancy (in the second and third trimesters). Fetal radiation dose was independently assessed for each patient, and an analysis was made of fetal radiation doses using the measurements of activity in the fetuses at various stages of pregnancy. Results: Six 18F-FDG PET studies in 5 pregnant patients were analyzed. The 18F-FDG PET scans were obtained in early pregnancy (n = 1), the second trimester (n = 2), and the third trimester (n = 3). The fetal dose exposure from 18F-FDG PET studies was estimated to range from 1.1 to 2.43 mGy for various trimesters in pregnancy (except for the patient in the early stage of pregnancy, in whom activity in the whole uterus was considered, and the fetal dose was estimated to be 9.04 mGy). All patients delivered healthy infants with no visible abnormalities at term. Conclusion: The fetal radiation dose from 18F-FDG PET studies is quite low and significantly below the threshold dose for deterministic effects due to radiation exposure to the fetus. The estimated fetal radiation exposure in our cases was slightly lower than existing estimates on fetal dose exposure, and as more data become available, the current fetal dose estimates may have to be modified accordingly. By addressing an important safety issue dealing with performing medically necessary 18F-FDG PET in pregnant patients, these data are expected to help in the imaging workup of cancer patients during pregnancy.Keywords
This publication has 18 references indexed in Scilit:
- Absorbed 18F-FDG Dose to the Fetus During Early Pregnancy: FIGURE 1.Journal of Nuclear Medicine, 2010
- Utilization of Imaging in Pregnant Patients: 10-year Review of 5270 Examinations in 3285 Patients—1997–2006Radiology, 2009
- Radiation exposure during transmission measurements: comparison between CT- and germanium-based techniques with a current PET scannerEuropean Journal of Nuclear Medicine and Molecular Imaging, 2003
- Obstetrical deliveries associated with maternal malignancy in California, 1992 through 1997American Journal of Obstetrics and Gynecology, 2001
- Dosimetry of transmission measurements in nuclear medicine: a study using anthropomorphic phantoms and thermoluminescent dosimetersEuropean Journal of Nuclear Medicine and Molecular Imaging, 1998
- Fetal and Fetal Brain Volume Estimation in the Third Trimester of Human Pregnancy Using Gradient Echo MR ImagingMagnetic Resonance Imaging, 1998
- Placental Transfer of Radiopharmaceuticals and Dosimetry in PregnancyHealth Physics, 1997
- Radiation Absorbed Dose to the Embryo/Fetus from RadiopharmaceuticalsHealth Physics, 1997
- FDG Uptake in Gestational SacClinical Nuclear Medicine, 1997
- First births to older mothers, 1970-86.American Journal of Public Health, 1989