Electrochemical analysis of antioxidant status of biological media in different sampling and storage conditions
Open Access
- 1 January 2024
- journal article
- research article
- Published by National Library of Serbia in Journal of the Serbian Chemical Society
- Vol. 89 (4) , 539-549
Abstract
The use of an electrochemical approach for assessment of the oxidative stress severity is a promising direction for point-of-care testing development, which is especially important for critically ill patients. The aim of this study was to determine the influence of different types of blood collection tubes (with clot activator and separating gel, lithium heparin, sodium citrate and K2EDTA) and storage conditions (at +25°C, +4°C and -23°C up to 5 days) on the electrochemical analysis of the antioxidant status of blood plasma, assessed by measuring the open circuit potential of platinum electrode (OCP, mV) and antioxidant capacity via cyclic voltammetry method (q, μC). It was obtained that blood collection tubes with lithium heparin and clot activator are the most suitable for the electrochemical analysis of antioxidant status of blood plasma, since they do not affect the results of measurements. Furthermore, data obtained during storage blood plasma samples in different temperature conditions indicate that it is preferable to perform electrochemical analysis in fresh samples.Keywords
This publication has 22 references indexed in Scilit:
- Comparative evaluation of blood collection tubes for clinical chemistry analysisClinica Chimica Acta, 2021
- Electrochemical Methods for Assessment of Polytrauma OutcomesElectroanalysis, 2020
- Optimization of a diagnostic platform for oxidation–reduction potential (ORP) measurement in human plasmaRedox Report, 2018
- Preanalytic of total antioxidant capacity assays performed in serum, plasma, urine and salivaClinical Biochemistry, 2017
- Short-Term Stability of Biomarkers of Oxidative Stress and Antioxidant Status in Human SerumISRN Biomarkers, 2013
- Stability study of 81 analytes in human whole blood, in serum and in plasmaClinical Biochemistry, 2012
- Study of adsorption of citrate on Pt by CV and EQCMElectrochimica Acta, 2008
- Stability Studies of Twenty-Four Analytes in Human Plasma and SerumClinical Chemistry, 2002
- Electrochemical and chemical reactions in baths for plating amorphous alloysJournal of Applied Electrochemistry, 1991
- Anodic Oxidation of Ethylenediaminetetraacetic Acid on Pt in Acid Sulfate SolutionsJournal of the Electrochemical Society, 1972