Rapidly switchable matrix-assisted laser desorption/ionization and electrospray quadrupole-time-of-flight mass spectrometry for protein identification
Authors:
- 1 June 2000
- journal article
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 11 (6) , 493-504
Abstract
We describe a new interface for a prototype quadrupole-quadrupole-time-of-flight (TOF) mass spectrometer (Centaur, Sciex) that allows rapid switching between electrospray ionization (ESI) and matrix-assisted laser desorption/ionization (MALDI) modes of operation. Instrument performance in both modes is comparable (i.e., resolution approximately 10,000 FWHM, mass accuracy <10 ppm, sensitivity approximately 1 fmol) because the ion source is decoupled from the TOF mass analyzer by extensive gas collisions in the quadrupole stages of the instrument. The capacity to obtain side-by-side high quality ESI and MALDI mass spectra from a single proteolytic mixture greatly facilitates the identification of proteins and elucidation of their primary structures. Improved strategies for protein identification result from this ability to measure spectra using both ionization modes in the same instrument and to perform MS/MS on singly charged as well as multiply charged ions. Examples are provided to demonstrate the utility and performance of the modified instrument.Keywords
This publication has 28 references indexed in Scilit:
- Use of Mass Spectrometric Methods for Protein Identification in Receptor ResearchJournal of Receptors and Signal Transduction, 1999
- Human Transformer-2-beta Gene (SFRS10): Complete Nucleotide Sequence, Chromosomal Localization, and Generation of a Tissue-Specific IsoformGenomics, 1998
- Protein indentification using mass spectrometric informationElectrophoresis, 1998
- Rapid micro-scale proteolysis of proteins for MALDI-MS peptide mapping using immobilized trypsinInternational Journal of Mass Spectrometry and Ion Processes, 1997
- Peer Reviewed: Internet-Based Analytical Chemistry Resources: A Model ProjectAnalytical Chemistry, 1996
- Preparation and properties of pure, full-length Ic1R protein of escherichia coli. Use of time-of-flight mass spectrometry to investigate the problems encounteredProtein Science, 1996
- Femtomole sequencing of proteins from polyacrylamide gels by nano-electrospray mass spectrometryNature, 1996
- High Sensitivity Collisionally-activated Decomposition Tandem Mass Spectrometry on a Novel Quadrupole/Orthogonal-acceleration Time-of-flight Mass SpectrometerRapid Communications in Mass Spectrometry, 1996
- Electrospray and Taylor-Cone theory, Dole's beam of macromolecules at last?International Journal of Mass Spectrometry and Ion Processes, 1994
- Secondary electron resolved mass spectrometry of electrosprayed ionsInternational Journal of Mass Spectrometry and Ion Processes, 1994