Turbulence in Blood Damage Modeling
- 30 March 2016
- journal article
- Published by SAGE Publications in The International Journal of Artificial Organs
- Vol. 39 (4) , 160-165
Abstract
Purpose: To account for the impact of turbulence in blood damage modeling, a novel approach based on the generation of instantaneous flow fields from RANS simulations is proposed. Methods: Turbulent flow in a bileaflet mechanical heart valve was simulated using RANS-based (SST k-ω) flow solver using FLUENT 14.5. The calculated Reynolds shear stress (RSS) field is transformed into a set of divergence-free random vector fields representing turbulent velocity fluctuations using procedural noise functions. To consider the random path of the blood cells, instantaneous flow fields were computed for each time step by summation of RSS-based divergence-free random and mean velocity fields. Using those instantaneous flow fields, instantaneous pathlines and corresponding point-wise instantaneous shear stresses were calculated. For a comparison, averaged pathlines based on mean velocity field and respective viscous shear stresses together with RSS values were calculated. Finally, the blood damage index (hemolysis) was integrated along the averaged and instantaneous pathlines using a power law approach and then compared. Results: Using RSS in blood damage modeling without a correction factor overestimates damaging stress and thus the blood damage (hemolysis). Blood damage histograms based on both presented approaches differ. Conclusions: A novel approach to calculate blood damage without using RSS as a damaging parameter is established. The results of our numerical experiment support the hypothesis that the use of RSS as a damaging parameter should be avoided.Keywords
This publication has 17 references indexed in Scilit:
- The effect of turbulent viscous shear stress on red blood cell hemolysisJournal of Artificial Organs, 2014
- A viscoelastic model of shear-induced hemolysis in laminar flowBiorheology, 2013
- Computational Characterization of Flow and Hemolytic Performance of the UltraMag Blood Pump for Circulatory SupportArtificial Organs, 2010
- Rethinking turbulence in bloodBiorheology, 2009
- Numerical modeling of blood damage: current status, challenges and future prospectsExpert Review of Medical Devices, 2006
- Numerical Estimation of Blood Damage in Artificial OrgansArtificial Organs, 2004
- The Power‐law Mathematical Model for Blood Damage Prediction: Analytical Developments and Physical InconsistenciesArtificial Organs, 2004
- DiscussionJournal of Biomechanics, 1999
- The geometry of the aortic root in health, at valve disease and after valve replacementJournal of Biomechanics, 1990