Separation and Preconcentration of Platinum Group Metals and Gold on Modified Silica and XAD Sorbents in the Presence of Cationic Surfactants for Their Determination by ICP-AES
- 1 January 2002
- journal article
- Published by Institute of Organic Chemistry & Biochemistry in Collection of Czechoslovak Chemical Communications
- Vol. 67 (4) , 454-470
Abstract
Various modified silica sorbents and unmodified silica were tested for the separation and preconcentration of 10-200 ng cm-3from 50-1 000 cm3sample volume of platinum group metals (PGMs), Pt(IV, II), Pd(II), Ir(IV), Rh(III), Os(VI), Ru(IV) and Au(III) in the form of ion associates of their chloro and bromo complexes with cationic surfactants. [1-(Ethoxycarbonyl)pentadecyl]trimethylammonium bromide (Septonex®), benzyl(dodecyl)dimethylammonium bromide (Sterinol®), trimethyl(tetradecyl)ammonium bromide or hexadecyl(trimethyl)ammonium chloride and 0.1 M HCl or 0.1 M HBr are suitable for the purpose. 100% recovery for Pd(II), Pt(IV) and Au(III) was obtained with octadecyl silicas Separon™ SGX C18, Separon™ SGX RPS and Phenyl™ silica in the presence of 0.006 M Septonex® or 0.003 M Sterinol®. The retained PGMs and Au(III) were eluted with acetonitrile and determined by inductively coupled plasma atomic emission spectrometry (ICP-AES) after evaporation of organic solvent in the presence of 0.1 M HCl. The enrichment factor on Separon™ SGX RPS reaches 100. A 1 000 : 1 excess of Cl-, NO3-, SO42-, Na+, K+, Ca2+, Mg2+, Fe3+or Al3+does not interfere with the preconcentration of PGMs and Au(III) on this sorbent. With the silica-based anion exchanger Separon™ SGX AX, the 100% recovery is observed for Ir(IV), Pd(II), Pt(IV) when the elution is performed with 5 M HCl or 5 M HNO3. Macroporous sorbents Amberlite™ XAD2 and Amberlite™ XAD4 are suitable for the retention of Au(III), Pd(II) and Pt(IV) from 0.1 M HCl and 0.006 M Septonex®. 100% recovery is achieved using acetonitrile as eluent but there is no preference of these sorbents to modified silica. In this way, the recovery of 0.1-0.2 μg cm-3Au(III), Pd(II), Pt(IV) was also successfully tested with spiked matrices of soil extracts, power station dust samples and natural waters.Keywords
This publication has 15 references indexed in Scilit:
- Control of interferences in the determination of Pt, Pd and Rh in airborne particulate matter by inductively coupled plasma mass spectrometryAnalytica Chimica Acta, 2000
- Preconcentration and Separation of Gold on Modified Silica GelCollection of Czechoslovak Chemical Communications, 2000
- Comparison of some analytical performance characteristics in inductively coupled plasma spectrometry of platinum group metals and goldTalanta, 1999
- Preconcentration of platinum group metals on modified silicagel and their determination by inductively coupled plasma atomic emission spectrometry and inductively coupled plasma mass spectrometry in airborne particulatesTalanta, 1999
- Hospital effluents as a source for platinum in the environmentScience of The Total Environment, 1997
- HPLC of Platinum Metals and Gold Based on Their Bromo ComplexesCollection of Czechoslovak Chemical Communications, 1997
- Determination of platinum in plants by emission spectrometry after preconcentration on modified silicagelTalanta, 1993
- Platinum traces in airborne particulate matter. Determination of whole content, particle size distribution and soluble platinumAnalytical and Bioanalytical Chemistry, 1993
- The kinetics of some isotopic exchange reactions of anionic ruthenium-(II), -(III), and -(IV) chloro-complexes in concentrated aqueous H36Cl solutionsJournal of the Chemical Society A: Inorganic, Physical, Theoretical, 1968
- Evidence for ruthenium(II) chloro complexes in aqueous hydrochloric acid solutions and some oxidation-reduction reactions of ruthenium(II), -(III), and -(IV) chloro complexesAustralian Journal of Chemistry, 1967