The phenol red thread tear test in large Psittaciformes
Authors:
- 23 February 2006
- journal article
- Published by Wiley in Veterinary Ophthalmology
- Vol. 9 (2) , 109-113
Abstract
To develop a standard method for measuring tear production in large Psittaciformes using the phenol red thread (PRT) tear test. To establish mean PRT tear test values in clinically normal pet birds and to assess the reproducibility of the test. Two geographically distinct populations of healthy, large Psittaciformes (pilot study and study population). Species groups include: cockatoo (17), macaw (22), Amazon (10), African gray (1), eclectus (1) and pionus (1). The PRT was placed under the upper eyelid and both eyelids were held closed throughout the test. The PRT tear test was repeated after 2 months in the pilot study and after approximately 5 min in the study population. The mean PRT tear test values for the pilot study were OD=28.2 mm/15 s (+/- 6.3 mm), OS=24.1 mm/15 s (+/- 6.6 mm) and OD=25.4 mm/15 s (+/- 3.3 mm), OS=25.5 mm/15 s (+/- 5.2 mm), for the first and second visits respectively. The mean PRT tear test value for the study population was: OD=19.8 mm/15 s (+/- 4.3 mm), OS=20.1 (+/- 3.9 mm) and OD=20.0 mm/15 s (+/- 4.5 mm), OS=19.1 mm/15 s (+/- 3.3 mm), for the first and second tests respectively. There was poor repeatability between tests. Results suggest that the PRT tear test is a practical method for measuring tear production in large Psittaciformes, although adaptations to the established diagnostic method are necessary to overcome some anatomical differences present in birds. Good reproducibility of the PRT tear test could not be demonstrated in a clinically normal population of birds but geographic location appears to significantly influence results.Keywords
This publication has 9 references indexed in Scilit:
- The Repeatability of Clinical Measurements of Dry EyeCornea, 2004
- Schirmer tear test results in normal horses and ponies: effect of age, season, environment, sex, time of day and placement of stripsVeterinary Ophthalmology, 2003
- The fluctuation of tear production in the dogJournal of the American Animal Hospital Association, 1998
- Tonometry of normal eyes in raptorsAmerican Journal of Veterinary Research, 1994
- LensesOphthalmology, 1987
- Evaluation of Tear Formation in the Dog, Using a Modification of the Schirmer Tear TestJournal of the American Veterinary Medical Association, 1975
- Keratoconjunctivitis Sicca in DogsJournal of the American Veterinary Medical Association, 1971
- Clinical Vertebral Artery Cerebral Blood Flow MeasurementEuropean Neurology, 1971
- Effect of temperature and humidity in the Schirmer tear test.British Journal of Ophthalmology, 1967