Analytical Validation of the High Concentrated Thrombin Time‐To‐Reptilase Time Ratio: A Proposed Assay for Monitoring Unfractionated Heparin in Patients With Low Fibrinogen Levels
- 9 March 2025
- journal article
- Published by Wiley in International Journal of Laboratory Hematology
- Vol. 47 (4) , 738-747
Abstract
Introduction: This study aimed to evaluate the analytical performance of the high‐concentrated thrombin time‐to‐reptilase time (hcTT/RT) ratio as a novel assay to neutralize fibrinogen effects and improve accuracy in unfractionated heparin (UFH) monitoring and to validate its use in clinical samples with low fibrinogen levels.Methods: A total of 240 heparin‐spiked plasma samples, prepared from 30 normal plasma samples with varying UFH concentrations, were analyzed. The hcTT/RT ratio's correlation with anti‐FXa activity and its sensitivity and specificity were compared with the hcTT assay. Additionally, 89 clinical samples from UFH‐treated patients with low fibrinogen levels were analyzed to validate the assay in clinical settings.Results: Both hcTT and the hcTT/RT ratio demonstrated strong correlations with anti‐FXa activity (R2 = 0.76 and 0.75, respectively). The hcTT/RT ratio outperformed hcTT in detecting subtherapeutic UFH levels, achieving higher diagnostic accuracy (AUC: 0.99 vs. 0.98, p < 0.001), greater sensitivity (89.2% vs. 86.7%), and perfect specificity (100.0% vs. 98.3%), with comparable performance for supratherapeutic UFH levels. Notably, the hcTT/RT ratio remained unaffected by low fibrinogen concentrations. In the validation study, the hcTT/RT ratio showed a stronger correlation with anti‐FXa activity than activated partial thromboplastin time and hcTT alone (R2 = 0.72 vs. 0.63 and 0.72 vs. 0.67, respectively) and had no significant correlation with fibrinogen levels (Spearman's r = −0.01).Conclusions: The hcTT/RT ratio is a reliable assay for monitoring UFH, especially in patients with low fibrinogen levels. Further large‐scale clinical studies are needed to evaluate its practical application in clinical settings.Keywords
This publication has 30 references indexed in Scilit:
- International council for standardisation in haematology recommendations on fibrinogen assays, thrombin clotting time and related tests in the investigation of bleeding disordersInternational Journal of Laboratory Hematology, 2023
- Fibrinogen and antithrombin III are associated with in-hospital mortality among critically ill patients with acute kidney injuryRenal Failure, 2022
- Validation of high concentrated thrombin time assay for unfractionated heparin monitoringJournal of Clinical Laboratory Analysis, 2022
- Preanalytical Variables in Coagulation Testing: Setting the Stage for Accurate ResultsSeminars in Thrombosis and Hemostasis, 2019
- Monitoring of heparins in antithrombin-deficient patientsThrombosis Research, 2019
- Should we abandon the APTT for monitoring unfractionated heparin?Thrombosis Research, 2017
- Pharmacokinetic/pharmacodynamic model for unfractionated heparin dosing during cardiopulmonary bypassBritish Journal of Anaesthesia, 2017
- Reptilase Time (RT)2013
- A proposed model to monitor heparin therapy using the concentrated thrombin time which allows standardisation of reagents and improved estimation of heparin concentrationsBlood Coagulation & Fibrinolysis, 1996
- The Therapeutic Range for Heparin Therapy: Relationship between Six Activated Partial Thromboplastin Time Reagents and Two Heparin AssaysThrombosis and Haemostasis, 1996