Unveiling the Relationships Between Seismocardiogram Signals, Physical Activity Types and Metabolic Equivalent of Task Scores
- 28 July 2022
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 70 (2) , 479-487
Abstract
Objective: The diagnosis of metabolic syndrome and cardiovascular disorders can highly benefit from physical activity and energy expenditure assessment. In this study, we investigated the relationship between metabolic equivalent of task (MET) scores and seismocardiogram (SCG)-derived parameters. Methods: We worked with the PAMAP2 dataset and focused on the 3-axial chest acceleration data. We first segmented the 3-axial SCG signals into respiration (0-1 Hz), cardiac vibrations (1-20 Hz) and heart sounds (20-40 Hz) components. Additionally, we investigated their combinations: 0-20 Hz, 1-40 Hz and 0-40 Hz. We then windowed each signal, and extracted time and frequency domain features from each window. Using the MET scores and activity types, we trained linear regression and random forest classification models first using 80-20% split, then with leave-one-subject-out cross-validation (LOSO-CV). Additionally, we investigated the significance of each feature and axis. Results: For the 80-20% task, the best performing frequency bands were 0-1 Hz, 0-20 Hz, and 0-40 Hz, which yielded a (MET mean-squared-error, classification accuracy) pair of (0.354, 0.952), (0.367, 0.904), and (0.377, 0.914), respectively. When LOSO-CV was applied, we obtained (1.059, 0.865), (0.681, 0.868), and (0.804, 0.875) for each band, respectively. Additionally, our results revealed that the lateral axis provides the most critical information about cardiorespiratory effect of performed activities. Conclusion: Different SCG components can provide unique and substantial contributions to activity and energy expenditure assessment. Significance: This framework can be leveraged in the design of wearable systems for monitoring the activity and energy expenditure levels, and understanding their relationship with underlying cardiorespiratory parameters.Keywords
This publication has 38 references indexed in Scilit:
- Posture and Activity Recognition and Energy Expenditure Estimation in a Wearable PlatformIEEE Journal of Biomedical and Health Informatics, 2015
- Estimating Energy Expenditure With Multiple Models Using Different Wearable SensorsIEEE Journal of Biomedical and Health Informatics, 2015
- Ballistocardiography and Seismocardiography: A Review of Recent AdvancesIEEE Journal of Biomedical and Health Informatics, 2014
- Wearable seismocardiography: Towards a beat-by-beat assessment of cardiac mechanics in ambulant subjectsAutonomic Neuroscience, 2013
- Accelerometer Output and MET Values of Common Physical ActivitiesMedicine & Science in Sports & Exercise, 2010
- Improving assessment of daily energy expenditure by identifying types of physical activity with a single accelerometerJournal of Applied Physiology, 2009
- A novel method for using accelerometer data to predict energy expenditureJournal of Applied Physiology, 2006
- Retest reliability of spatiotemporal gait parameters in children and adultsGait & Posture, 1998
- Metabolic equivalents (METS) in exercise testing, exercise prescription, and evaluation of functional capacityClinical Cardiology, 1990
- The frequency content of gaitJournal of Biomechanics, 1985