Abstract
In this work we dosimetrically evaluated the clinical implementation of a commercial Monte Carlo treatment planning software (PEREGRINE, North American Scientific, Cranberry Township, PA) intended for quality assurance (QA) of intensity modulated radiation therapy treatment plans. Dose profiles calculated in homogeneous and heterogeneous phantoms using this system were compared to both measurements and simulations using the EGSnrc Monte Carlo code for the 6 MV beam of a Varian CL21EX linear accelerator. For simple jaw‐defined fields, calculations agree within 2% of the dose at with measurements in homogeneous phantoms with the exception of the buildup region where the calculations overestimate the dose by up to 8%. In heterogeneous lung and bone phantoms the agreement is within 3%, on average, up to 5% for a field. We tested two consecutive implementations of the MLC model. After matching the calculated and measured MLC leakage, simulations of static and dynamic MLC‐defined fields using the most recent MLC model agreed to within 2% with measurements.Keywords
Funding Information
- Canadian Institutes of Health Research (CIHR, MOP 57828)
This publication has 19 references indexed in Scilit:
- Evaluation of the first commercial Monte Carlo dose calculation engine for electron beam treatment planningMedical Physics, 2003
- Sensitivity of megavoltage photon beam Monte Carlo simulations to electron beam and other parametersMedical Physics, 2002
- Description and dosimetric verification of the PEREGRINE Monte Carlo dose calculation system for photon beams incident on a water phantomMedical Physics, 2001
- VMC++, Electron and Photon Monte Carlo Calculations Optimized for Radiation Treatment Planning2001
- Monte Carlo study of correction factors for Spencer–Attix cavity theory at photon energies at or above 100 keVMedical Physics, 2000
- Accurate condensed history Monte Carlo simulation of electron transport. I. EGSnrc, the new EGS4 versionMedical Physics, 2000
- VMC++, a fast MC algorithm for Radiation Treatment planning2000
- Correlated histogram representation of Monte Carlo derived medical accelerator photon‐output phase spaceMedical Physics, 1999
- Backscatter into the beam monitor chamber: Implications for dosimetry of asymmetric collimatorsMedical Physics, 1993
- Fluence perturbation in photon beams under nonequilibrium conditionsMedical Physics, 1986