Bone structure determined by HR-MDCT does not correlate with micro-CT of lumbar vertebral biopsies: a prospective cross-sectional human in vivo study
Open Access
- 10 September 2020
- journal article
- research article
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 15 (1) , 1-7
Abstract
Background: Osteoporosis is characterized by a deterioration of bone structure and quantity that leads to an increased risk of fractures. The primary diagnostic tool for the assessment of the bone quality is currently the dual-energy X-ray absorptiometry (DXA), which however only measures bone quantity. High-resolution multidetector computed tomography (HR-MDCT) offers an alternative approach to assess bone structure, but still lacks evidence for its validity in vivo. The objective of this study was to assess the validity of HR-MDCT for the evaluation of bone architecture in the lumbar spine. Methods: We conducted a prospective cross-sectional study to compare the results of preoperative lumbar HR-MDCT scans with those from microcomputed tomography (μCT) analysis of transpedicular vertebral body biopsies. For this purpose, we included patients undergoing spinal surgery in our orthopedic department. Each patient underwent preoperative HR-MDCT scanning (L1-L4). Intraoperatively, transpedicular biopsies were obtained from intact vertebrae. Micro-CT analysis of these biopsies was used as a reference method to assess the actual bone architecture. HR-MDCT results were statistically analyzed regarding the correlation with results from μCT. Results: Thirty-four patients with a mean age of 69.09 years (± 10.07) were included in the study. There was no significant correlation for any of the parameters (bone volume/total volume, trabecular separation, trabecular thickness) between μCT and HR-MDCT (bone volume/total volume: r = − 0.026 and p = 0.872; trabecular thickness: r = 0.074 and r = 6.42; and trabecular separation: r = − 0.18 and p = 0.254). Conclusion: To our knowledge, this is the first study comparing in vivo HR-MDCT with μCT analysis of vertebral biopsies in human patients. Our findings suggest that lumbar HR-MDCT is not valid for the in vivo evaluation of bone architecture in the lumbar spine. New diagnostic tools for the evaluation of osteoporosis and preoperative orthopedic planning are urgently needed.Keywords
This publication has 37 references indexed in Scilit:
- Surgical Stabilization of the Spine in the Osteoporotic PatientOrthopedic Clinics of North America, 2013
- Surgical Treatment Options in Patients With Impaired Bone QualityClinical Orthopaedics and Related Research, 2011
- Simultaneous screening for osteoporosis at CT colonography: Bone mineral density assessment using MDCT attenuation techniques compared with the DXA reference standardJournal of Bone and Mineral Research, 2011
- Determinants of the mechanical behavior of human lumbar vertebrae after simulated mild fractureJournal of Bone and Mineral Research, 2010
- Radiation exposure in X-ray-based imaging techniques used in osteoporosisEuropean Radiology, 2010
- Trabecular Bone Structure Analysis in the Osteoporotic Spine Using a Clinical In Vivo Setup for 64-Slice MDCT Imaging: Comparison to μCT Imaging and μFE ModelingJournal of Bone and Mineral Research, 2009
- Assessment of trabecular bone structure of the calcaneus using multi-detector CT: Correlation with microCT and biomechanical testingBone, 2009
- Evaluation of trabecular mechanical and microstructural properties in human calcaneal bone of advanced age using mechanical testing, μCT, and DXAJournal of Biomechanics, 2008
- Mehrschicht-CT zur Strukturanalyse des trabekulären Knochens - Vergleich mit Mikro-CT und biomechanischer FestigkeitRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2004
- Age-related decrements in bone mineral density in women over 65Journal of Bone and Mineral Research, 1992