Minimally Invasive Per-Catheter Patent Ductus Arteriosus Occlusion in Dogs Using a Prototype Duct Occluder
Authors:
Open Access
- 1 January 2008
- journal article
- clinical trial
- Published by Oxford University Press (OUP) in Journal of Veterinary Internal Medicine
- Vol. 22 (1) , 129-134
Abstract
Background: Per-catheter patent ductus arteriosus (PDA) occlusion in dogs with devices intended for humans is associated with technical difficulties, high rates of procedure abandonment, device migration, and residual ductal flow. Hypothesis: Use of a custom-made canine duct occluder (Amplatz Canine Duct Occluder, ACDO) would be feasible in dogs of varying weights and somatotypes and effective in occluding a wide range of PDA shapes and sizes. Animals: Eighteen client-owned dogs of various breeds with PDA. Weights ranged from 3.8 to 32.3 kg (median, 17.8 kg), and angiographic minimal ductal diameters ranged from 1.1 to 6.9 mm (median, 3.7 mm). Ductal morphologies included types IIA, IIB, and III. Methods: Per-catheter PDA occlusion with the ACDO was performed in all dogs. Persistent or recurrent ductal flow was assessed at the end of the procedure by angiography and at 1 day, 3 months, and ≥12 months after the procedure by echocardiography. Results: Successful ACDO placement was achieved in all 18 dogs. One dog required a 2nd procedure with a larger ACDO after the 1st device migrated to the pulmonary vasculature. Complete occlusion was confirmed in 17 of 18 dogs during the procedure, as well as at 1 day and 3 months after the procedure, and in 12 of 13 dogs evaluated at ≥12 months after the procedure. Conclusions and Clinical Importance: Per-catheter PDA occlusion in dogs with the ACDO is feasible and effective in dogs of a wide range of weights and somatotypes and with PDAs of varying shapes and sizes.Keywords
This publication has 12 references indexed in Scilit:
- Transcatheter embolisation of patent ductus arteriosus using an Amplatzer vascular plug in six dogsJournal of Small Animal Practice, 2007
- Echocardiographic and Angiographic Comparison of Ductal Dimensions in Dogs with Patent Ductus ArteriosusJournal of Veterinary Internal Medicine, 2007
- Angiographic classification of patent ductus arteriosus morphology in the dogJournal of Veterinary Cardiology, 2006
- Transcatheter closure of patent ductus arteriosus in a dog with a peripheral vascular occlusion deviceJournal of Veterinary Cardiology, 2006
- Immediate and Late Outcomes of Transarterial Coil Occlusion of Patent Ductus Arteriosus in DogsJournal of Veterinary Internal Medicine, 2006
- Long‐term follow‐up of dogs with patent ductus arteriosusJournal of Small Animal Practice, 2003
- Closure of large patent ductus arteriosus with a self‐expanding duct occluder in two dogsJournal of Small Animal Practice, 2002
- Review of left‐to‐right shunting patent ductus arteriosus and short term outcome in 98 dogsJournal of Small Animal Practice, 2002
- Transcatheter Closure of Patent Ductus Arteriosus Using Occluding Spring CoilsJournal of Veterinary Internal Medicine, 2000
- Transcatheter Occlusion of a Patent Ductus Arteriosus in a Newfoundland Puppy Using the Gianturco-Grifka Vascular Occlusion DeviceJournal of Veterinary Internal Medicine, 1996