Comparison of a Multi-Scenario Robustness Evaluation Method with Measurements for Proton Teletherapy
Open Access
Abstract
Background/Objectives: Multi-scenario calculational methods have been used to evaluate proton teletherapy plan robustness but few studies have been performed to determine the accuracy of these calculational methods. This study evaluates a multi-scenario method by comparing calculations to measurements made in phantoms that simulate the effects of possible uncertainties. Methods: Plans were made using four phantoms in which the delivered dose was highly sensitive to positional and penetration uncertainties. The effects of alignment and penetration uncertainties on the dose distributions of each of those phantoms were simulated by performing calculations using nine different uncertainty scenarios and comparing the calculations to measurements with induced physical alignment displacements. Measured dose distributions were obtained by exposing films placed inside the phantoms and extracting multiple linear profiles. The maximum and minimum doses obtained for each of the calculational scenarios were compared with the measured dose profiles. In addition, comparisons of DVHs for nominal and uncertainty scenarios were performed. Results: The results showed that, under the influence of uncertainties, the minimum dose for the four phantoms decreased by more than 20 Gy, the V95% coverage fluctuated by more than 10%, but the maximum dose parameter changed by less than 5 Gy. This was expected, as no margins for uncertainties were applied around the targets. The envelope bounded by the maximum and minimum possible calculated doses contained most of the measurements, although the shapes of the dose profiles displayed some mismatches for wedge and head phantoms. There were a few points where the measured maximum dose for bone and lung slab phantom cases was slightly higher than the maximum dose calculated from the nine scenarios. Conclusions: This study demonstrates that a nine-scenario method can adequately evaluate the robustness of simple mono-directional plans containing heterogeneities.Keywords
This publication has 29 references indexed in Scilit:
- Optimization of the planning process with an in-house treatment information, management, and planning systemRadiation Medicine and Protection, 2022
- Small spot size versus large spot size: Effect on plan quality for lung cancer in pencil beam scanning proton therapyJournal of Applied Clinical Medical Physics, 2022
- Practical robustness evaluation in radiotherapy – A photon and proton-proof alternative to PTV-based plan evaluationRadiotherapy and Oncology, 2019
- Spatial correlation of linear energy transfer and relative biological effectiveness with suspected treatment‐related toxicities following proton therapy for intracranial tumorsMedical Physics, 2019
- Robustness Analysis for External Beam Radiation Therapy Treatment Plans: Describing Uncertainty Scenarios and Reporting Their Dosimetric ConsequencesPractical Radiation Oncology, 2019
- Robust Proton Treatment Planning: Physical and Biological OptimizationSeminars in Radiation Oncology, 2018
- Visualization of a variety of possible dosimetric outcomes in radiation therapy using dose-volume histogram bandsPractical Radiation Oncology, 2012
- EVA space suit proton and electron threshold energy measurements by XCT and range shiftingRadiation Measurements, 2006
- Radiation tests of the extravehicular mobility unit space suit for the international space station using energetic protonsRadiation Measurements, 2006
- Characterization of the radiation shielding properties of US and Russian EVA suits using passive detectorsRadiation Measurements, 2006