Malleable stylet in difficult intubation: a modified technique
Authors:
Open Access
- 1 August 2014
- journal article
- research article
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 113 (2) , 298-299
Abstract
Editor—In anaesthesia practice, 1–4% of patients require multiple attempts during tracheal intubation. A difficult intubation is a complex interaction of patient factors, clinical setting, and the skills of the practitioner.1 A number of intubation aids and equipment including intubating guides, lighted stylets, bougies, laryngeal mask airways, and video-laryngoscopes are now available for unanticipated difficult tracheal intubation.1,2 In situations when airway adjuncts are not readily available, a malleable stylet which is usually a part of basic equipment for tracheal intubation may be used with a different technique. The conventional method of using a malleable stylet during tracheal intubation is well known. We describe our experience of the use of a malleable stylet in adult patients with laryngoscopic view of Cormack–Lehane (CL) grade III even after optimal external laryngeal manipulation. An adult malleable stylet (Portex®, Smith Medical, non-USA) which has a soft tip (1.0 cm) was used with a modified technique in difficult intubations. The malleable stylet was well lubricated and was inserted with the tip of the stylet curved upwards 20° protruding nearly 2.0 cm beyond the tip of the tracheal tube (TT) (Fig. 1 a). The anaesthesiologist performing laryngoscopy inserted the assembly in the mouth and directed it along the dorsal surface of the epiglottis so that the tip of the stylet came to lie in front of the glottic opening (not visible in patients with CL grade III). This was followed by a synchronized movement of insertion of 1.0 cm of TT by the anaesthetist along with simultaneous gradual withdrawal of the stylet by 1.0 cm by an assistant (Fig. 1 b). The tip of the TT at this point was in front of the glottic opening, which was then inserted, further in the trachea while the stylet was gradually withdrawn (Fig. 1 c). So far, this modified technique has resulted in successful tracheal intubation in our patients with CL grade III with no adverse effects or airway trauma. The principle of our technique is somewhat similar to the use of a bougie but differs as bougie lacks inherent strength and rigidity of a malleable stylet. However, we would like to emphasize that the modified technique be used only by an experienced anaesthetist with a trained assistant when other advanced airway gadgets are not readily available.Keywords
This publication has 1 reference indexed in Scilit:
- 2012 Emery A. Rovenstine Memorial LectureAnesthesiology, 2013