Effects of preoperative plasma exchange therapy with albumin replacement fluid on blood coagulation in patients undergoing ABO-incompatible living-donor kidney transplantation using rotational thromboelastometry
Open Access
- 19 June 2018
- journal article
- research article
- Published by Springer Nature in BMC Anesthesiology
- Vol. 18 (1) , 1-7
Abstract
ABO-incompatible living-donor kidney transplantation (LDKT) requires immunotherapy and plasma exchange therapy (PEX). PEX with albumin replacement fluid reportedly decreases fibrinogen levels. However, no reports have described the effects of PEX with albumin replacement fluid on blood coagulation parameters and blood loss during the perioperative period. Therefore, we investigated the effects of preoperative PEX on blood coagulation parameters and blood loss during the perioperative period in patients undergoing ABO-incompatible LDKT as measured by rotational thromboelastometry (ROTEM®). Twenty-eight patients undergoing LDKT were divided into the PEX group (ABO incompatible with PEX, n = 13) and non-PEX group (ABO compatible without PEX, n = 15). ROTEM® parameters, standard laboratory test parameters, bleeding volume, and transfusion volume were compared between PEX and non-PEX group. MCEplatelet, which represents platelet contribution to clot strength and where “MCE” stands for maximum clot elasticity, was calculated from the difference in MCE between EXTEM and FIBTEM. The bleeding volume during surgery and the intensive care unit (ICU) stay was significantly higher in the PEX than non-PEX group (p < 0.01). Maximum clot firmness (MCF) of EXTEM (MCFEXTEM), MCFFIBTEM, and MCEplatelet was significantly lower in the PEX than non-PEX group (p < 0.01). In the PEX group, the bleeding volume during surgery was very strongly correlated with the baseline MCFEXTEM and MCEplatelet, and the bleeding volume during the ICU stay was strongly correlated with the postoperative MCFEXTEM and MCEplatelet. These results suggest that the increased blood loss in the PEX group during surgery and the ICU stay was associated with decreased platelet contribution to clot strength as measured by ROTEM®. UMIN-Clinical Trial Registry UMIN000018355 . Registered 21 July 2015.Keywords
This publication has 31 references indexed in Scilit:
- Diastolic dysfunction of the left ventricle is associated with pulmonary edema after renal transplantationActa Anaesthesiologica Scandinavica, 2013
- Role of Plasma Exchange in ABO-incompatible Kidney TransplantationAnnals of Laboratory Medicine, 2012
- Complications of therapeutic plasma exchange: A prospective study of 1,727 proceduresJournal of Clinical Apheresis, 2007
- Cost reduction of perioperative coagulation management in cardiac surgery: value of ‘bedside’ thrombelastography (ROTEM)☆European Journal of Cardio-Thoracic Surgery, 2007
- Perioperative fluid management in renal transplantation: a narrative review of the literatureTransplant International, 2006
- Evaluation of the Contribution of Platelets to Clot Strength by Thromboelastography in Rabbits: The Role of Tissue Factor and Cytochalasin DAnesthesia & Analgesia, 2000
- Evaluation of the Contribution of Platelets to Clot Strength by Thromboelastography in Rabbits: The Role of Tissue Factor and Cytochalasin DAnesthesia & Analgesia, 2000
- Use of abciximab-Modified Thrombelastography in Patients Undergoing Cardiac SurgeryAnesthesia & Analgesia, 1999
- Use of abciximab-Modified Thrombelastography in Patients Undergoing Cardiac SurgeryAnesthesia & Analgesia, 1999
- Coagulation Changes during Packed Red Cell Replacement of Major Blood LossAnesthesiology, 1988