Validation of the Japan Society of Clinical Chemistry (JSCC) recommended reference measurement procedure for glycated albumin determination
- 23 August 2025
- journal article
- Published by SAGE Publications in Annals of Clinical Biochemistry: International Journal of Laboratory Medicine
- Vol. 63 (2) , 123-131
Abstract
Background: To clarify the fundamental characteristics of the Japan Society of Clinical Chemistry reference measurement procedure (JSCC RMP) for glycated albumin (GA), an additional performance study was performed and the correlation between the HPLC method and JSCC RMP was re-evaluated. Methods: Repeatability, detection limit, addition recovery, uncertainty of measurement, inter-laboratory comparison, correlation between JSCC RMP and HPLC method were evaluated. Results: The coefficient of variation (CV) of the total repeatability for the nine pretreated samples including isotope dilution and hydrolysis, defining that the averages of each of nine MS measurement samples are independent measurement vials, was 1.0%( n = 9). The limit of detection and Quantification of the GA values were 7.4 and 29.5 mmol/mol, respectively. Addition recovery rates were 99.6%–100.4%. The strong correlation (r = 0.999) of measured six serum samples between two laboratories was observed. Certified values and expanded uncertainties for JCCRM 611-2 (M, H, HH) using the JSCC RMP were as follows: JCCRM 611-2M: 232 and 9 mmol/mol, JCCRM611-2H: 359 and 14 mmol/mol, JCCRM611-2HH: 556 and 22 mmol/mol, respectively. The regression equation obtained using the Passing–Bablok method was GA (%) HPLC = 0.0523 × GA (mmol/mol) JSCC RMP + 1.315. Conclusion: The basic performance of the JSCC reference procedure for GA measurement was good, and similar results were obtained at other facilities, so it was considered to be robust and suitable as a reference method for GA measurement. Additionally, an equation was established to convert JSCC RMP (mmol/mol) values to the HPLC% values used in clinical practice.Keywords
This publication has 6 references indexed in Scilit:
- 6. Glycemic Goals and Hypoglycemia: Standards of Care in Diabetes—2024Diabetes Care, 2023
- Development of a matrix-based candidate reference material for human glycated albumin using isotope-dilution liquid chromatography/tandem mass spectrometryAnalytica Chimica Acta, 2022
- Committee on Diabetes Mellitus Indices of the Japan Society of Clinical Chemistry-recommended reference measurement procedure and reference materials for glycated albumin determinationAnnals of Clinical Biochemistry: International Journal of Laboratory Medicine, 2015
- An enzymatic method for the measurement of glycated albumin in biological samplesClinica Chimica Acta, 2002
- GLYCATED ALBUMIN ANALYZER1996
- Kinetics of HbA1c, Glycated Albumin, and Fructosamine and Analysis of Their Weight Functions Against Preceding Plasma Glucose LevelDiabetes Care, 1995