Introduction: A fenestrated endograft (FE) is the first-line endovascular option for juxta and pararenal abdominal aortic aneurysms. A physician-modified stent-graft (PMSG) and laser in situ fenestration (LISF) have emerged to circumvent manufacturing delays, anatomic standards, and the procedure’s cost raised by FE. The objective was to compare different fenestrations from a mechanical point of view. Methods: In total, five Zenith Cook fenestrations (Cook Medical, Bloomington, IN, USA) and five Anaconda fenestrations (Terumo Company, Inchinnan, Scotland, UK) were included in this study. Laser ISF and PMSG were created on a Cook TX2 polyethylene terephthalate (PET) cover material (Cook Medical, Bloomington, IN, USA). In total, five LISFs and fifty-five PMSG were created. All fenestrations included reached an 8 mm diameter. Radial extension tests were then performed to identify differences in the mechanical behavior between the fenestration designs. The branch pull-out force was measured to test the stability of assembling with a calibrated 8 mm branch. Fatigue tests were performed on the devices to assess the long-term outcomes of the endograft with an oversized 9 mm branch. Results: The results revealed that at over 2 mm of oversizing, the highest average radial strength was 33.4 ± 6.9 N for the Zenith Cook fenestration. The radial strength was higher with the custom-made fenestrations, including both Zenith Cook and Anaconda fenestrations (9.5 ± 4.7 N and 4.49 ± 0.28 N). The comparison between LISF and double loop PMSG highlighted a higher strength value compared with LISF (3.96 N ± 1.86 vs. 2.7 N ± 0.82; p= 0.018). The diameter of the fenestrations varied between 8 and 9 mm. As the pin caliber inserted in the fenestration was 9 mm, one could consider that all fenestrations underwent an “elastic recoil” after cycling. The largest elastic recoil was observed in the non-reinforced/OC fenestrations (40%). A 10% elastic recoil was observed with LISF. Conclusion: In terms of mechanical behavior, the custom-made fenestration produced the highest results in terms of radial and branch pull-out strength. Both PMSG and LISF could be improved with the standardization of the fenestration creation protocol.Keywords
This publication has 25 references indexed in Scilit:
- Editor's Choice – European Society for Vascular Surgery (ESVS) 2019 Clinical Practice Guidelines on the Management of Abdominal Aorto-iliac Artery AneurysmsEuropean Journal of Vascular and Endovascular Surgery, 2019
- In Situ Antegrade Laser Fenestrations During Endovascular Aortic RepairEuropean Journal of Vascular and Endovascular Surgery, 2018
- An Experimental Study of Laser in situ Fenestration of Current Aortic EndograftsEuropean Journal of Vascular and Endovascular Surgery, 2018
- In Situ Laser Fenestration Is a Feasible Method for Revascularization of Aortic Arch During Thoracic Endovascular Aortic RepairJournal of the American Heart Association, 2017
- Design of a sensorized guiding catheter for in situ laser fenestration of endovascular stentComputer Assisted Surgery, 2017
- Endovascular Aortic Repair2017
- Clinical outcomes and material properties of in situ fenestration of endovascular stent graftsJournal of Vascular Surgery, 2016
- Experimental Evaluation of Complete Endovascular Arch Reconstruction by In Situ Retrograde FenestrationThe Annals of Thoracic Surgery, 2014
- In Situ Laser Fenestration for Revascularization of the Left Subclavian Artery During Emergent Thoracic Endovascular Aortic RepairJournal of Endovascular Therapy, 2012
- In Situ Stent-Graft Fenestration to Preserve the Left Subclavian ArteryJournal of Endovascular Therapy, 2004