Respiratory changes in subclavian vein diameters predicts fluid responsiveness in intensive care patients: a pilot study
Authors:
- 29 January 2018
- journal article
- research article
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 32 (6) , 1049-1055
Abstract
The present pilot study investigated whether respiratory variation in subclavian vein (SCV) diameters correlates with fluid responsiveness in mechanically ventilated patients. Monocentric, prospective clinical study on fluid responsiveness in adult sedated, mechanically ventilated ICU patient, monitored with the PiCCO™ system (Pulsion Medical System, Germany), and requiring a fluid challenge (FC). A 10-min fluid bolus of 500 mL of 0.9% saline was administered. Cardiac output (CO) and dynamic parameters [stroke volume variation (SVV) and pulse pressure variation (PPV)] measured by transpulmonary thermodilution and pulse contour analysis (PiCCO™) as well as classical hemodynamic parameters were recorded at baseline and after FC. Fluid responsiveness was described as an increase in CO of ≥ 15%. Ultrasound measurements obtained in the subclavian long-axis view were used to calculate the SCVvariability index. A cut-off value for SCV variation for the prediction of fluid responsiveness was determined using receiver operating curve (ROC) analysis. Nine of 20 FCs (45%) induced an increase in CO of ≥ 15%. At baseline, the SCVvariability index was greater in responders than in non-responders (34.0 ± 21.4 vs. 9.0 ± 5.5; p = 0.0005). Diagnostic performance for the SCVvariability index revealed a cut-off value of 14 with a sensitivity of 100% [Confidence interval (CI) 95% (90; 100)] and a specificity of 82% [CI 95% (48; 98)] for the prediction of fluid responsiveness. Other parameters, such as SVV and PPV, could not predict fluid responsiveness. The correlation coefficient between CO variation and the SCVvariability index was 0.73 (p < 0.001). The SCVvariability index was a reliable, non-invasive parameter for the prediction of fluid responsiveness at the bedside of mechanically ventilated, critically ill patients in this pilot study.Keywords
This publication has 22 references indexed in Scilit:
- Focused Critical Care EchocardiographyCritical Care Medicine, 2013
- Sonographic evaluation of intravascular volume status in the surgical intensive care unit: a prospective comparison of subclavian vein and inferior vena cava collapsibility indexJournal of Surgical Research, 2013
- Extravascular lung water is an independent prognostic factor in patients with acute respiratory distress syndrome*Critical Care Medicine, 2013
- Radial–femoral concordance in time and frequency domain-based estimates of systemic arterial respiratory variationJournal of Clinical Monitoring and Computing, 2012
- pROC: an open-source package for R and S+ to analyze and compare ROC curvesBMC Bioinformatics, 2011
- Fluid resuscitation in septic shock: A positive fluid balance and elevated central venous pressure are associated with increased mortality*Critical Care Medicine, 2011
- Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: A systematic review of the literature*Critical Care Medicine, 2009
- Cardiac filling pressures are not appropriate to predict hemodynamic response to volume challenge*Critical Care Medicine, 2007
- Superior vena caval collapsibility as a gauge of volume status in ventilated septic patientsIntensive Care Medicine, 2004
- New Concepts in the Diagnosis and Fluid Treatment of Circulatory ShockAnesthesia & Analgesia, 1979