Myocardial Rotation but Not Circumferential Strain Is Transducer Angle Dependent: A Speckle Tracking Echocardiography Study
Authors:
- 12 August 2010
- journal article
- research article
- Published by Wiley in Echocardiography
- Vol. 27 (7) , 809-814
Abstract
Doppler derived strain analysis has been shown to be angle dependent. Speckle tracking analysis using 2D echocardiographic images is thought to provide angle independent parameters of regional and global myocardial function. This study sought to evaluate whether myocardial circumferential strain and rotation derived from automatic frame-by-frame tracking of natural acoustic markers is dependent on angulation of the transducer. In 48 healthy volunteers (mean age 36 ± 3 years, 20 male) parasternal short-axis views at apical level were obtained as follows: at the standard parasternal position (5th intercostal space) with a most possible circular short-axis image of the left ventricle (angulation 1), at an angulation of the transducer by 20° from this standard position to the apex (angulation 2) and at an angulation of the transducer by 20° to the base of the left ventricle (angulation 3). Using an automatic frame-by-frame tracking system of natural acoustic echocardiographic markers (EchoPAC, GE Ultrasound, Horton, Norway) circumferential strain and rotation were calculated for six segments within a short-axis circumference. Image quality was sufficient for acquisition and analysis of images at all three-transducer angulation in 90% of the analyzed segments. Rotation was measured to be 7.7 ± 1.2° at angulation 1, 2.7 ± 0.9° at angulation 2 and 4.3 ± 1.1° at angulation 3 (p < 0.05). Average circumferential strain data was found to be -27.2 ± 5.1% at angulation 1, -26.5 ± 3.8% at angulation 2 and 28.9 ± 4.4% at angulation 3 (p = 0.287). Circumferential strain analysis is not dependent on transducer angulation. In contrast, determination of myocardial rotation is dependent on transducer angulation. Therefore, accurate transducer angulation has to be taken care of if rotation measurements are performed.Keywords
This publication has 23 references indexed in Scilit:
- Insights into Left Ventricular Function from the Time Course of Regional and Global Rotation by Speckle Tracking EchocardiographyEchocardiography, 2009
- Assessment of subendocardial vs. subepicardial left ventricular rotation and twist using two-dimensional speckle tracking echocardiography: comparison with tagged cardiac magnetic resonanceEuropean Heart Journal, 2008
- Importance of Transducer Position in the Assessment of Apical Rotation by Speckle Tracking EchocardiographyJournal of the American Society of Echocardiography, 2008
- Assessment of Left Ventricular Dyssynchrony by Speckle Tracking Strain ImagingJACC, 2008
- Augmentation of Left Ventricular Apical Endocardial Rotation With Inotropic Stimulation Contributes to Increased Left Ventricular Torsion and Radial Strain in Normal Subjects Quantitative Assessment Utilizing a Novel Automated Tissue Tracking TechniqueCirculation Journal, 2007
- Analysis of myocardial deformation based on pixel tracking in two dimensional echocardiographic images enables quantitative assessment of regional left ventricular functionHeart, 2006
- Comparison of Two-Dimensional Speckle and Tissue Velocity Based Strain and Validation With Harmonic Phase Magnetic Resonance ImagingThe American Journal of Cardiology, 2006
- New Noninvasive Method for Assessment of Left Ventricular RotationCirculation, 2005
- Two-dimensional strain–a novel software for real-time quantitative echocardiographic assessment of myocardial functionJournal of the American Society of Echocardiography, 2004
- Quantitative Assessment of Intrinsic Regional Myocardial Deformation by Doppler Strain Rate Echocardiography in HumansCirculation, 2002