Evaluation of Energy Efficiency Performance of Heated Windows
Authors:
- Hari Swarup JammulamadakaHJHari Swarup Jammulamadaka
- Bhaskaran GopalakrishnanBGBhaskaran Gopalakrishnan
- Subodh ChaudhariSCSubodh Chaudhari
- Senthil SundaramoorthySSSenthil Sundaramoorthy
- Akash Rajesh MehtaAMAkash Rajesh Mehta
- Roseline MostafaRMRoseline Mostafa
Open Access
- 1 January 2022
- journal article
- research article
- Published by Tech Science Press in Energy Engineering
- Vol. 119 (1) , 1-16
Abstract
Fenestration systems are widely used across the world. There is expansive research on window configurations, frames, and glazing technology, but not enough research has been published on reducing window heat loss through heat application to a pane. The presented study attempted to evaluate the performance of heated windows by developing an experimental setup to test a window at various temperatures by varying the power input to the window. Heated double pane window was installed in an insulated box. A temperature gradient was developed across the window by cooling one side of the window using gel-based ice packs. The other face of the window was heated by enabling power at different wattages through the window. The temperature of the inside and outside panes, current and voltage input, and temperature of the room and box were recorded. The data was used to calculate the apparent effective resistance of the window when not being heated vs. when being heated. The study concluded that, when window temperature was maintained close to the room temperature, the heated double pane window is effective in reducing heat loss by as much as 50% as compared to a non-heated double pane window. When temperature of the window was much higher than the room temperature, the heat loss through the window increased beyond that of a non-heated window. The issues encountered during the current stages of experiments are noted, and recommendations are provided for future studies.Keywords
This publication has 21 references indexed in Scilit:
- Impact of Curtain Wall Configurations on Building Energy Performance in the Perimeter Zone for a Cold ClimateEnergy Procedia, 2015
- Methodology for selecting fenestration systems in heating dominated climatesApplied Energy, 2015
- Analysis of a Hybrid Solar Window for Building IntegrationEnergy Procedia, 2014
- On the conformity of floor heating systems with sleeping in the eastern-style beds; physiological responses and thermal comfort assessmentBuilding and Environment, 2012
- Key elements of and material performance targets for highly insulating window framesEnergy and Buildings, 2011
- Optimization of insulation thickness for different glazing areas in buildings for various climatic regions in TurkeyApplied Energy, 2011
- A review of HVAC systems requirements in building energy regulationsEnergy and Buildings, 2011
- Floor heating and cooling combined with displacement ventilation: Possibilities and limitationsEnergy and Buildings, 2010
- Flow patterns and thermal comfort in a room with panel, floor and wall heatingEnergy and Buildings, 2008
- Efficiency of electrically heated windowsEnergy and Buildings, 2004