Rapid Determination of Ethylene Oxide and 75 VOCs in Ambient Air with Canister Sampling and Associated Growth Issues
Open Access
- 22 March 2021
- journal article
- research article
- Published by MDPI AG in Separations
- Vol. 8 (3) , 35
Abstract
A canister-based sampling method along with preconcentrator-Gas chromatography-Mass Spectrometry (GC-MS) analysis was applied to ethylene oxide (EtO or EO) and 75 other volatile organic compounds (VOCs) in ambient air. Ambient air can contain a large variety of VOCs, and thorough analysis requires non-discriminatory sampling and a chromatographic method capable of resolving a complex mixture. Canister collection of whole air samples allows for the collection of a wide range of volatile compounds, while the simultaneous analysis of ethylene oxide and other VOCs allows for faster throughput than separate methods. The method presented is based on US EPA Method TO-15A and allows for the detection of EtO from 18 to 2500 pptv. The method has an average accuracy of 104% and precision of 13% relative standard deviation (RSD), with an instrument run time of 32 min. In addition, a link between canister cleanliness and ethylene oxide growth is observed, and potential mechanisms and cleaning strategies are addressed.Keywords
This publication has 10 references indexed in Scilit:
- Identification and quantification of ethylene oxide in sterilized medical devices using multiple headspace GC/MS measurementJournal of Pharmaceutical and Biomedical Analysis, 2018
- Temperature-programmable low thermal mass silicon micromachined gas chromatography and differential mobility detection for the fast analysis of trace level of ethylene oxide in medical work place atmospheresJournal of Chromatography A, 2012
- Rapid determination of ethylene oxide with fiber-packed sample preparation needleJournal of Chromatography A, 2009
- Ethylene oxide sterilization of medical devices: A reviewAmerican Journal of Infection Control, 2007
- Laboratory and field validations of a solid-phase microextraction device for the determination of ethylene oxideJournal of Chromatography A, 2003
- Determination of ethylene oxide by solid-phase microextraction device with on-fiber derivatizationJournal of Chromatography A, 2003
- Ethylene oxide pollution evaluation Part II: Sampling on HBr-treated charcoal tubesChromatographia, 1986
- Determination of ethylene oxide in air by gas chromatographyAnalytical Chemistry, 1984
- Analysis of ethylene oxide — worker exposureAIHA Journal, 1979
- A new method for monitoring personal exposure to ethylene oxide in the occupational environmentAIHA Journal, 1977